Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.80 g/cm³ |
Water absorption rate | | ASTM D570 | 0.60 % |
flammability | Test Condition | Test Method | Test Result |
---|
Limiting Oxygen Index | | ASTM D2863 | 36 % |
UL flame retardant rating | | UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ASTM D638 | 61.4 MPa |
bending strength | | ASTM D790 | 170 MPa |
compressive strength | | ASTM D695 | 269 MPa |
shear strength | | ASTM D732 | 92.4 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 570 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | ASTM D149 | 22 kV/mm |
Dissipation Factor | | ASTM D150 | 0.011 |
Dissipation Factor | | ASTM D150 | 0.010 |
arc resistance | | ASTM D495 | 130 sec |
Compared to the Leakage Tracking Index (CTI) | | UL 746 | PLC 1 |
High arc combustion index (HAI) | | UL 746 | PLC 0 |
dielectric strength | | ASTM D149 | 17 kV/mm |
Hot wire ignition (HWI) | | UL 746 | PLC 0 sec |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Linear coefficient of thermal expansion | | ASTM D696 | 2E-05 cm/cm/°C |
thermal conductivity | | ASTMC177 | 0.26 W/m/K |
RTI Elec | | UL 746 | 130 °C |
RTI | | UL 746 | 160 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.