PPSU TECASON™ P MT ENSINGER GERMANY

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTM D7921.29 g/cm³
Water absorption rateASTM D5700.37 %
Water absorption rateASTM D5701.1 %
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessASTM D785123
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94V-0
Mechanical propertiesTest ConditionTest MethodTest Result
bending strengthASTM D79091.0 MPa
compressive strengthASTM D69598.9 MPa
Tensile modulusASTM D6382340 MPa
tensile strength ASTM D63869.6 MPa
elongationASTM D63860 %
Flexural modulusASTM D7902410 MPa
Impact resistanceTest ConditionTest MethodTest Result
Suspended wall beam without notch impact strengthASTM D256690 J/m
Electrical performanceTest ConditionTest MethodTest Result
dielectric constantASTM D1503.44
Volume resistivityASTM D2571E+15 ohms·cm
dielectric strengthASTM D14914 kV/mm
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureASTM D648214 °C
Heat distortion temperatureASTM D648207 °C
Heat distortion temperatureASTM D648218 °C
Linear coefficient of thermal expansionASTM D6965.6E-05 cm/cm/°C
specific heatASTMC3511130 J/kg/°C
maximum service temperature182 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.