Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183 | 1.12 g/cm³ | |
Melt volume flow rate | ISO 1133 | 16.0 cm³/10min | |
Shrinkage rate | ISO 294-4 | 0.50to0.60 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-2 | 2600 MPa | |
tensile strength | ISO 527-2 | 48.0 MPa | |
Nominal tensile fracture strain | ISO 527-2 | 10 % | |
Rockwell hardness | R-Scale | ISO 2039-2 | 115 |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179 | 3.0 kJ/m² | |
ISO 179 | 5.0 kJ/m² | ||
Impact strength of simply supported beam without notch | ISO 179 | 26 kJ/m² | |
ISO 179 | 60 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Volume resistivity | IEC 60093 | >1.0E+18 ohms·cm | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 0 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
vicat | ISO 306/A50 | 100 °C | |
ISO 306/B50 | 92.0 °C | ||
Linear coefficient of thermal expansion | ISO 11359-2 | 8.0E-5to1.1E-4 cm/cm/°C | |
thermal conductivity | DIN 52612 | 0.17 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.