physical property | Test Condition | Test Method | Test Result |
---|
melt mass-flow rate | | ISO 1133 | 14 g/10min |
Melt volume flow rate | | ISO 1133 | 12.0 cm3/10min |
Shrinkage rate | | ISO 294-4 | 1.7 % |
Shrinkage rate | | ISO 294-4 | 1.8 % |
Water absorption rate | | ISO 62 | 0.30 % |
flammability | Test Condition | Test Method | Test Result |
---|
FMVSS flammability | | FMVSS302 | B |
burning rate | | ISO 3795 | 28 mm/min |
UL flame retardant rating | | UL 94 | HB |
UL flame retardant rating | | UL 94 | HB |
UL flame retardant rating | | IEC 60695-11-10,-20 | HB |
UL flame retardant rating | | IEC 60695-11-10,-20 | HB |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
Emission | | VDA275 | <8.00 mg/kg |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2 | 3000 Mpa |
tensile strength | | ISO 527-2 | 66.0 Mpa |
Tensile strain | | ISO 527-2 | 11 % |
Nominal tensile fracture strain | | ISO 527-2 | 23 % |
Tensile creep modulus | | ISO 899-1 | 2400 Mpa |
Tensile creep modulus | | ISO 899-1 | 1600 Mpa |
Flexural modulus | | ISO 178 | 2800 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO 179/1eU | 130 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | 160 kJ/m² |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/B | 164 °C |
Heat distortion temperature | | ISO 75-2/A | 97.0 °C |
melting temperature | | ISO 11357-3 | 178 °C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 1.2E-04 cm/cm/°C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 1.2E-04 cm/cm/°C |
AnnealingTemperature | | | 160 °C |
AnnealingTime-Optional | | | 30.0 min/mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.