Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ASTM D955 | 0.20to0.65 % |
Shrinkage rate | | ISO 294-4 | 0.10to0.91 % |
Water absorption rate | | ASTM D570 | 0.35to1.8 % |
Water absorption rate | | ISO 62 | 0.63to5.8 % |
Water absorption rate | | ISO 62 | 5.0to8.0 % |
Water absorption rate | | ISO 62 | 1.5to2.0 % |
density | | ASTM D792 | 1.23to1.70 g/cm³ |
density | | ISO 1183 | 1.20to1.58 g/cm³ |
hardness | Test Condition | Test Method | Test Result |
---|
Shore hardness | | ISO 868 | 84to85 |
ball-indentation hardness | | ISO 2039-1 | 160to274 MPa |
flammability | Test Condition | Test Method | Test Result |
---|
Burning wire flammability index | | IEC 60695-2-12 | 650to960 °C |
Hot filament ignition temperature | | IEC 60695-2-13 | 650to960 °C |
Limiting Oxygen Index | | ISO 4589-2 | 21to27 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ISO 527-2 | 110to242 MPa |
tensile strength | | ASTM D638 | 143to174 MPa |
Tensile strain | | ISO 527-2 | 2.0to3.0 % |
Tensile strain | | ASTM D638 | 3.0to5.1 % |
Tensile strain | | ISO 527-2 | 1.9to4.0 % |
Flexural modulus | | ASTM D790 | 4230to9520 MPa |
Flexural modulus | | ISO 178 | 5440to9110 MPa |
bending strength | | ASTM D790 | 130to291 MPa |
bending strength | | ISO 178 | 144to286 MPa |
Tensile modulus | | ISO 527-2 | 5200to16800 MPa |
tensile strength | | ISO 527-2 | 80.0to250 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179 | 4.9to15 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179 | 29to95 kJ/m² |
Suspended wall beam without notch impact strength | | ISO 180 | 39to51 kJ/m² |
Impact strength of cantilever beam gap | | ASTM D256 | 43to160 J/m |
Impact strength of cantilever beam gap | | ISO 180 | 2.9to16 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC 60093 | 1.0E+11到2.5E+14 ohms |
Volume resistivity | | IEC 60093 | 1.0E+12到2.5E+15 ohms·cm |
dielectric strength | | IEC 60243-1 | 21to35 kV/mm |
relative permittivity | | IEC 60250 | 3.56 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 0 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Continuous use temperature | | ASTM D794 | 100to230 °C |
vicat | | ISO 306 | 195to241 °C |
melting temperature | | ISO 11357-3 | 260 °C |
melting temperature | | ISO 3146 | 242to262 °C |
Heat distortion temperature | | ASTM D648 | 210to250 °C |
Heat distortion temperature | | ISO 75-2/A | 199to253 °C |
Heat distortion temperature | | ISO 75-2/C | 60.0to176 °C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 1.5E-5到3.0E-5 cm/cm/°C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 7.0E-5到1.1E-4 cm/cm/°C |
RTI Elec | | UL 746 | 65.0to67.1 °C |
Heat distortion temperature | | ISO 75-2/B | 224to256 °C |
RTI Imp | | UL 746 | 65.0to66.1 °C |
RTI | | UL 746 | 65.0to67.1 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.