Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | 内部方法 | 0.40to0.60 % | |
Water absorption rate | ISO 62 | 0.60 % | |
ISO 62 | 0.20 % | ||
density | ISO 1183 | 1.18 g/cm³ | |
Melt volume flow rate | ISO 1133 | 23.0 cm³/10min |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | V-0 | |
UL 94 | 5VB | ||
Burning wire flammability index | IEC 60695-2-12 | 960 °C | |
IEC 60695-2-12 | 960 °C | ||
Hot filament ignition temperature | IEC 60695-2-13 | 775 °C | |
IEC 60695-2-13 | 825 °C | ||
IEC 60695-2-13 | 775 °C | ||
IEC 60695-2-13 | 825 °C | ||
IEC 60695-2-13 | 775 °C | ||
IEC 60695-2-13 | 825 °C | ||
UL flame retardant rating | UL 94 | V-0 | |
Limiting Oxygen Index | ISO 4589-2 | 31 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ASTM D638 | 2760 MPa | |
ISO 527-2/1 | 2750 MPa | ||
tensile strength | ASTM D638 | 63.9 MPa | |
Yield | ISO 527-2/50 | 63.1 MPa | |
ASTM D638 | 47.5 MPa | ||
elongation | Yield | ISO 527-2/50 | 4.0 % |
ASTM D638 | 65 % | ||
Break | ISO 527-2/50 | 35 % | |
Flexural modulus | ISO 178 | 2440 MPa | |
bending strength | ISO 178 | 94.5 MPa | |
tensile strength | Break | ISO 527-2/50 | 46.4 MPa |
elongation | ASTM D638 | 4.1 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO 179/1eU | 无断裂无断裂 | |
Impact strength of cantilever beam gap | ASTM D256 | 100 J/m | |
Charpy Notched Impact Strength | ISO 179/1eA | 1010 kJ/m² | |
ISO 179/1eA | 33 kJ/m² | ||
Impact strength of simply supported beam without notch | ISO 179/1eU | 无断裂 | |
Suspended wall beam without notch impact strength | ISO 180/1U | 无断裂无断裂 | |
Impact strength of cantilever beam gap | ASTM D256 | 480 J/m | |
ISO 180/1A | 12 kJ/m² | ||
ISO 180/1A | 25 kJ/m² | ||
Suspended wall beam without notch impact strength | ISO 180/1U | 无断裂无断裂 |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
relative permittivity | IEC 60250 | 2.90 | |
IEC 60250 | 2.90 | ||
Dissipation Factor | IEC 60250 | 2E-03 | |
IEC 60250 | 2E-03 | ||
IEC 60250 | 7E-03 | ||
Compared to the Leakage Tracking Index (CTI) | UL 746 | PLC 2 | |
Hot wire ignition (HWI) | UL 746 | PLC 3 | |
Surface Resistivity | IEC 60093 | >1.0E+15 ohms | |
Volume resistivity | IEC 60093 | >1.0E+15 ohms·cm | |
dielectric strength | IEC 60243-1 | 46 kV/mm | |
IEC 60243-1 | 31 kV/mm | ||
relative permittivity | IEC 60250 | 2.90 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
vicat | ISO 306/B120 | 106 °C | |
ball-indentation hardness | IEC 60695-10-2 | 通过 | |
Linear coefficient of thermal expansion | ISO 11359-2 | 8E-06 cm/cm/°C | |
ISO 11359-2 | 8E-06 cm/cm/°C | ||
RTI Elec | UL 746 | 85.0 °C | |
RTI Imp | UL 746 | 85.0 °C | |
RTI | UL 746 | 85.0 °C | |
Heat distortion temperature | ISO 75-2/Bf | 98.6 °C | |
ISO 75-2/Af | 88.1 °C | ||
vicat | ISO 306/B50 | 105 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.