PPO(PPE) PRL PPX-FRG10

0
  • Properties:
    Filler
    glass fiber reinforced material
    10%
    filler by weight

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
melt mass-flow rateASTMD12381.0到8.0 g/10min
Shrinkage rateASTMD9550.20到0.50 %
densityASTMD7921.15 g/cm³
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessASTMD785104
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL94V-1
UL flame retardant ratingUL94V-1
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO179/16.3 kJ/m²
Impact strength of cantilever beam gapASTMD25669 J/m
Impact strength of cantilever beam gapASTMD25685 J/m
Mechanical propertiesTest ConditionTest MethodTest Result
elongationBreakASTMD6385.0 %
Flexural modulusASTMD7903720 MPa
bending strengthASTMD790117 MPa
tensile strengthASTMD63877.2 MPa
tensile strengthASTMD63875.8 MPa
Electrical performanceTest ConditionTest MethodTest Result
Volume resistivityASTMD2571E+16 ohms·cm
Thermal performanceTest ConditionTest MethodTest Result
RTIUL74665.0 °C
ASTMD648132 °C
ASTMD648127 °C
vicatASTMD15253146 °C
RTI ElecUL74665.0 °C
RTI ElecUL74665.0 °C
RTI ImpUL74665.0 °C
RTI ImpUL74665.0 °C
RTIUL74665.0 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App

Top