Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
elongation | Yield | ASTM D-638 | DAM|5.5 % |
elongation | Yield | ASTM D-638 | 51%RH|- % |
Basic performance | Test Condition | Test Method | Test Result |
---|
tensile strength | | ASTM D-638 | 50%RH|41.4 MPa |
tensile strength | Yield | ASTM D-638 | DAM|50 MPa |
tensile strength | Yield | ASTM D-638 | 50%RH|- MPa |
elongation | Break | ASTM D-638 | DAM|60 % |
elongation | Break | ASTM D-638 | 51%RH|210 % |
tensile strength | | ASTM D-638 | DAM|51.7 MPa |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Flexural modulus | | ASTM D-790 | DAM|1689 MPa |
Flexural modulus | | ASTM D-790 | 52%RH|-862 MPa |
bending strength | | ASTM D-790 | DAM|68 J/m |
bending strength | | ASTM D-790 | 53%RH|- J/m |
Impact Strength | | ASTM D-256 | DAM|907 % |
Impact Strength | | ASTM D-256 | 53%RH|1068 % |
Longitudinal to transverse strain ratio | | | DAM|0.41 MPa |
Longitudinal to transverse strain ratio | | | 52%RH|- MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric constant | | ASTM D-150 | DAM|3.2 |
dielectric constant | | ASTM D-150 | 51%RH|5.5 |
dielectric constant | | ASTM D-150 | DAM|3.2 |
dielectric constant | | ASTM D-150 | 51%RH|4.5 |
dielectric constant | | ASTM D-150 | 52%RH|3.2 |
Loss factor | | ASTM D-150 | DAM|0.04 |
dielectric constant | | ASTM D-150 | DAM|2.9 |
Loss factor | | ASTM D-150 | 52%RH|0.20 |
Loss factor | | ASTM D-150 | DAM|0.01 |
Loss factor | | ASTM D-150 | 53%RH|0.10 |
Loss factor | | ASTM D-150 | DAM|0.02 |
Loss factor | | ASTM D-150 | 53%RH|0.05 |
Volume resistivity | | ASTM D-257 | DAM|1014 ohm.cm |
Volume resistivity | | ASTM D-257 | 54%RH|1013 ohm.cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTM D-648 | 52%RH|- ℃ |
| | ASTM D-696 | DAM|1.2 ℃ |
| | ASTM D-696 | 52%RH|- ℃ |
melting point | | ASTM D-3418 | 263 ℃ |
UL flame retardant rating | | UL94 | HB |
UL flame retardant rating | | UL94 | 0.81 |
| | ASTM D-648 | DAM|216 ℃ |
| | ASTM D-648 | 54%RH|- ℃ |
| | ASTM D-648 | DAM|71 ℃ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.