Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | 内部方法 | 0.63 % |
Water absorption rate | | ASTM D570 | 0.020 % |
Shrinkage rate | | 内部方法 | 0.11 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | ASTM D785 | 101 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Limiting Oxygen Index | | ISO 489 | 45 % |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
Solder resistance | | 内部方法 | 295 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Poisson's ratio | | | 7.58 0.41 |
tensile strength | | ASTM D638 | 134 Mpa |
elongation | | ASTM D638 | 4.5 % |
Flexural modulus | | ASTM D790 | 12100 Mpa |
Flexural modulus | | ASTM D790 | 4500 Mpa |
bending strength | | ASTM D790 | 145 Mpa |
bending strength | | ASTM D790 | 29.0 Mpa |
shear strength | | ASTM D732 | 53.0 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Suspended wall beam without notch impact strength | | ASTM D256 | 340 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Dissipation Factor | | ASTM D150 | 0.024 |
Dissipation Factor | | ASTM D150 | 0.030 |
arc resistance | | ASTM D495 | 180 sec |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 4 |
Volume resistivity | | ASTM D257 | 1E+15 ohms·cm |
dielectric constant | | ASTM D150 | 4.70 |
dielectric constant | | ASTM D150 | 4.10 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 270 °C |
Linear coefficient of thermal expansion | | 内部方法 | 1E-05 cm/cm/°C |
Linear coefficient of thermal expansion | | 内部方法 | 6.3E-05 cm/cm/°C |
thermal conductivity | | JISR2618 | 0.56 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.