physical property | Test Condition | Test Method | Test Result |
---|
melt mass-flow rate | | ASTM D1238 | 0.25 g/10min |
melt mass-flow rate | | ASTM D1238 | 23 g/10min |
Environmental stress cracking resistance | | ASTM D1693 | 50.0 hr |
hardness | Test Condition | Test Method | Test Result |
---|
Shore hardness | | ASTM D2240 | 59 |
Basic performance | Test Condition | Test Method | Test Result |
---|
density | | ASTM D-792 | 0.953 g/cm |
melt mass-flow rate | | ASTM D-1238 | 0.25 g/10min |
melt mass-flow rate | | ASTM D-1238 | 23 g/10min |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Environmental stress cracking resistance | | ASTM D-1693 | 50 hr |
tensile strength | | ASTM D-638 | 26.2 Mpa |
tensile strength | | ASTM D-638 | 25.5 Mpa |
elongation at yield | | ASTM D-638 | 6 % |
elongation at break | | ASTM D-638 | 900 % |
Flexural modulus | | ASTM D-790B | 1020 Mpa |
Impact strength of cantilever beam gap | | ASTM D-1822 | 210 KJ/m |
Shore hardness | | ASTM D-2240 | 59 |
tensile strength | | ASTM D638 | 26.2 Mpa |
tensile strength | | ASTM D638 | 25.5 Mpa |
elongation | | ASTM D638 | 6.0 % |
elongation | | ASTM D638 | 900 % |
Flexural modulus | | ASTM D790B | 1020 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D1822 | 210 kJ/m² |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D-648 | 70 °C |
vicat | | ASTM D-1525 | 129 °C |
melting temperature | | 内部方法 | 132 °C |
Crystallization peak temperature | | 内部方法 | 119 °C |
Heat distortion temperature | | ASTM D648 | 70.0 °C |
brittle temperature | | ASTM D746 | <-76.1 °C |
vicat | | ASTM D1525 | 129 °C |
melting temperature | | 内部方法 | 132 °C |
Crystallization peak temperature | | 内部方法 | 119 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.