PP PPH7060 TOTAI FRANCE

3
  • Usages:
    Toychipcontainer
  • Compare

Technical Data Sheet

optical performanceTest ConditionTest MethodTest Result
gloss45°,50.0 μm,铸造薄膜45°,50.0 μm,铸造薄膜ASTM D245785
turbidity50 μm,铸造薄膜50.0 μm,铸造薄膜ISO 147824 %
impact performanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gap23℃23℃ISO 1803.5 kJ/m²
mechanical propertiesTest ConditionTest MethodTest Result
Rockwell hardnessR-ScaleR-ScaleISO 2039-295
Bending modulusISO 1781450 Mpa
Tensile modulusISO 527-21550 Mpa
thermal performanceTest ConditionTest MethodTest Result
Melting temperatureDSCDSCISO 3146165 °C
Vicat softening temperatureB50--ISO 30687 °C
Vicat softening temperatureA50--ISO 306/A50152 °C
Hot deformation temperature0.45 MPa,Unannealed0.45 MPa,UnannealedISO 75-2/B100 °C
Hot deformation temperature1.8 MPa,Unannealed1.8 MPa,UnannealedISO 75-2/A55 °C
Physical propertiesTest ConditionTest MethodTest Result
densityISO 11830.905 g/cm³
Apparent densityISO 11830.53 g/cm³
melt mass-flow rate230℃,2.16kg230℃/2.16 kgISO 113312 g/10min
film propertiesTest ConditionTest MethodTest Result
Elmendorf tear strengthMD:50 μm,铸造薄膜MD : 2.0 mil, Cast FilmISO 6383-210 N
Dart impact50 μm,铸造薄膜50 μm,铸造薄膜ISO 7765-1270 g
Tensile strainTD,Break,50 μm,铸造薄膜TD : Break, 2.0 mil, Cast FilmISO 527-3600 %
Tensile strainMD,Break,50 μm,铸造薄膜MD : Break, 2.0 mil, Cast FilmISO 527-3500 %
Tensile strainYieldYieldISO 527-210 %
tensile strengthTD,Yield,50 μm,Blown FilmTD : Yield, 2.0 mil, Cast FilmISO 527-323 Mpa
tensile strengthMD,Yield,50 μm,Blown FilmMD : Yield, 2.0 mil, Cast FilmISO 527-323 Mpa
tensile strengthYieldYieldISO 527-232 Mpa
film thickness测试经测试50 µm
tensile strengthTD,Break,50 μm,Blown Film TD : Break, 2.0 mil, Cast FilmISO 527-334 Mpa
tensile strengthMD,Break,50 μm,Blown Film MD : Break, 2.0 mil, Cast FilmISO 527-344 Mpa
Elmendorf tear strengthTD:50 μm,铸造薄膜TD : 2.0 mil, Cast FilmISO 6383-228 N
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.