Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ASTM D955 | 0.30to0.50 % |
density | | ASTM D792 | 1.91 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|
Limiting Oxygen Index | | ASTM D2863 | 25 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
compressive strength | | ASTM D695 | 165 MPa |
bending strength | | ASTM D790 | 120 MPa |
Flexural modulus | | ASTM D790 | 17800 MPa |
tensile strength | | ASTM D638 | 70.0 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256A | 27 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
arc resistance | | ASTM D495 | 170 sec |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112,ASTMD3638 | PLC 0 |
Dissipation Factor | | ASTM D150 | 0.017 |
dielectric constant | | ASTM D150 | 4.00 |
dielectric strength | | ASTM D149 | 14 kV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
RTI | | UL 746 | 130 °C |
RTI Imp | | UL 746 | 130 °C |
RTI Elec | | UL 746 | 130 °C |
Linear coefficient of thermal expansion | | ASTME831 | 1.8E-05 cm/cm/°C |
Heat distortion temperature | | ASTM D648A | >260 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.