Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792 | 1.08 g/cm³ |
density | | ISO1183 | 1.08 g/cm³ |
melt mass-flow rate | | ASTMD1238 | 1.9 g/10min |
Melt volume flow rate | | ISO1133 | 24.0 cm³/10min |
Shrinkage rate | | ASTMD955 | 0.20to0.60 % |
Shrinkage rate | | ISO294-4 | 0.20to0.60 % |
Water absorption rate | | ASTMD570 | 0.10 % |
Water absorption rate | | ISO62 | 0.10 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | M-Scale | ASTMD785 | 70 |
| | ISO2039-1 | 168 MPa |
optical performance | Test Condition | Test Method | Test Result |
---|
refractive index | | ASTMD542 | 1.570 |
refractive index | | ISO489 | 1.570 |
transmissivity | | ASTMD1003 | 91.3 % |
Haze ratio | | ASTMD1003 | 0.30 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTMD256 | 21 J/m |
Impact strength of cantilever beam gap | | ISO180/A | 2.5 kJ/m² |
| | ISO180 | 12 kJ/m² |
Charpy Notched Impact Strength | | ISO179 | 1.5 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179 | 12 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTMD638 | 3240 MPa |
Tensile modulus | | ISO527-2 | 3300 MPa |
tensile strength | | ASTMD638 | 57.9 MPa |
Tensile stress | | ISO527-2 | 60.0 MPa |
elongation | Break | ASTMD638 | 2.1 % |
Tensile strain | | ISO527-2 | 2.5 % |
Flexural modulus | | ASTMD790 | 3100 MPa |
Flexural modulus | | ISO178 | 3400 MPa |
bending strength | | ASTMD790 | 97.2 MPa |
Bending stress | | ISO178 | 100 MPa |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO75-2/B | 90.0 °C |
| | ISO75-2/A | 80.0 °C |
vicat | | ASTMD15253 | 106 °C |
vicat | | ISO306/B50 | 98.0 °C |
maximum service temperature | | | 260 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.