ABS Novodur®  HD M203FC

68
  • Properties:
    Good disinfection perform
    High mobility
  • Usages:
    Shell
    Medical supplies
    Medical/nursing supplies

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
Melt volume flow rateISO 113331.0 cm3/10min
Shrinkage rateISO 294-40.40-0.70 %
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO 527-22400 Mpa
tensile strength ISO 527-246.0 Mpa
Tensile strainISO 527-22.6 %
Tensile strainISO 527-2>15 %
Flexural modulusISO 1782400 Mpa
bending strengthISO 17870.0 Mpa
ball-indentation hardnessISO 2039-1105 Mpa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of simply supported beam without notchISO 17990 kJ/m²
Impact strength of simply supported beam without notchISO 179110 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC 60093>1.0E+15 ohms
Volume resistivityIEC 60093>1.0E+15 ohms·cm
dielectric strengthIEC 60243-135 KV/mm
relative permittivityIEC 602503.00
relative permittivityIEC 602502.90
Dissipation FactorIEC 602505E-03
Dissipation FactorIEC 602509E-03
Compared to the Leakage Tracking Index (CTI)IEC 60112 V
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureISO 75-2/B98.0 °C
Heat distortion temperatureISO 75-2/A94.0 °C
vicatISO 306/B5099.0 °C
Linear coefficient of thermal expansionISO 11359-29E-05 cm/cm/°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App

Top