Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

ABS HD M203FC BASF GERMANY
Novodur®
Shell、Medical supplies、Medical/nursing supplies
Good disinfection perform、High mobility
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | BASF GERMANY/HD M203FC |
---|---|---|---|
Impact strength of simply supported beam without notch | -30°C | ISO 179 | 90 kJ/m² |
23°C | ISO 179 | 110 kJ/m² |
Mechanical properties | Test Condition | Test Method | BASF GERMANY/HD M203FC |
---|---|---|---|
Tensile modulus | ISO 527-2 | 2400 Mpa | |
Tensile strain | 断裂,23°C | ISO 527-2 | >15 % |
bending strength | ISO 178 | 70.0 Mpa | |
tensile strength | 屈服,23°C | ISO 527-2 | 46.0 Mpa |
Flexural modulus | ISO 178 | 2400 Mpa | |
Tensile strain | 屈服,23°C | ISO 527-2 | 2.6 % |
ball-indentation hardness | ISO 2039-1 | 105 Mpa |
Electrical performance | Test Condition | Test Method | BASF GERMANY/HD M203FC |
---|---|---|---|
Volume resistivity | IEC 60093 | >1.0E+15 ohms·cm | |
relative permittivity | 100Hz | IEC 60250 | 3.00 |
Dissipation Factor | 100Hz | IEC 60250 | 5E-03 |
dielectric strength | 1.50mm | IEC 60243-1 | 35 KV/mm |
relative permittivity | 1MHz | IEC 60250 | 2.90 |
Surface Resistivity | IEC 60093 | >1.0E+15 ohms | |
Dissipation Factor | 1MHz | IEC 60250 | 9E-03 |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | V |
physical property | Test Condition | Test Method | BASF GERMANY/HD M203FC |
---|---|---|---|
Shrinkage rate | ISO 294-4 | 0.40-0.70 % | |
Melt volume flow rate | 220°C/10.0kg | ISO 1133 | 31.0 cm3/10min |
Thermal performance | Test Condition | Test Method | BASF GERMANY/HD M203FC |
---|---|---|---|
Heat distortion temperature | 1.8MPa,退火,HDT | ISO 75-2/A | 94.0 °C |
vicat | ISO 306/B50 | 99.0 °C | |
Linear coefficient of thermal expansion | MD | ISO 11359-2 | 9E-05 cm/cm/°C |
Heat distortion temperature | 0.45MPa,Annealed,HDT | ISO 75-2/B | 98.0 °C |
Contact Us