Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO 1183/B | 1.20 g/cm³ |
melt mass-flow rate | | ASTM D1238 | 35 g/10min |
melt mass-flow rate | | ISO 1133 | 35 g/10min |
Shrinkage rate | | ASTM D955 | 0.50 % |
density | | ASTM D792 | 1.20 g/cm³ |
Shrinkage rate | | ISO 294-4 | 0.50 % |
Water absorption rate | | ASTM D570 | 0.15 % |
Water absorption rate | | ISO 62 | 0.15 % |
Water absorption rate | | ASTM D570 | 0.32 % |
Water absorption rate | | ISO 62 | 0.32 % |
optical performance | Test Condition | Test Method | Test Result |
---|
refractive index | | ASTM D542 | 1.586 |
refractive index | | ISO 489 | 1.586 |
transmissivity | | ASTM D1003 | 89.0 % |
Haze ratio | | ASTM D1003 | 1.0 % |
flammability | Test Condition | Test Method | Test Result |
---|
Hot filament ignition temperature | | IEC 60695-2-13 | 775 °C |
Limiting Oxygen Index | | ISO 4589-2 | 26 % |
UL flame retardant rating | | UL 94 | V-2 |
Burning wire flammability index | | IEC 60695-2-12 | 900 °C |
Burning wire flammability index | | IEC 60695-2-12 | 875 °C |
Burning wire flammability index | | IEC 60695-2-12 | 875 °C |
Hot filament ignition temperature | | IEC 60695-2-13 | 800 °C |
Hot filament ignition temperature | | IEC 60695-2-13 | 775 °C |
UL flame retardant rating | | UL 94 | V-2 |
UL flame retardant rating | | UL 94 | V-2 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile strain | Yield | ISO 527-2/50 | 6.0 % |
elongation | Break | ASTM D638 | 110 % |
Tensile strain | Break | ISO 527-2/50 | 110 % |
Flexural modulus | | ASTM D790 | 2400 MPa |
Tensile modulus | | ASTM D638 | 2300 MPa |
Flexural modulus | | ISO 178 | 2400 MPa |
bending strength | | ASTM D790 | 97.0 MPa |
bending strength | | ISO 178 | 97.0 MPa |
Tensile modulus | | ISO 527-2/50 | 2300 MPa |
tensile strength | Yield | ASTM D638 | 60.0 MPa |
tensile strength | Yield | ISO 527-2/50 | 60.0 MPa |
tensile strength | Break | ASTM D638 | 71.0 MPa |
tensile strength | Break | ISO 527-2/50 | 71.0 MPa |
elongation | Yield | ASTM D638 | 6.0 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179/1eA | 15 kJ/m² |
Impact strength of cantilever beam gap | | ASTM D256 | 1800 J/m |
Impact strength of cantilever beam gap | | ISO 180/A | 69 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | IEC 60093 | >1.0E+15 ohms·cm |
dielectric strength | | ASTM D149 | 17 kV/mm |
dielectric strength | | IEC 60243-1 | 17 kV/mm |
dielectric constant | | ASTM D150 | 3.00 |
dielectric constant | | ASTM D150 | 3.00 |
Dissipation Factor | | ASTM D150 | 1E-03 |
Dissipation Factor | | ASTM D150 | 2E-03 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 2 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
vicat | | ISO 306/B50 | 145 °C |
vicat | | ASTM D15255 | 145 °C |
Ball pressure temperature | | IEC 60335-1 | >125 °C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 7E-05 cm/cm/°C |
Heat distortion temperature | | ASTM D648 | 141 °C |
Heat distortion temperature | | ISO 75-2/B | 141 °C |
Heat distortion temperature | | ASTM D648 | 140 °C |
Heat distortion temperature | | ISO 75-2/A | 138 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.