physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ASTMD955 | 0.40 % |
Shrinkage rate | | ASTMD955 | 0.50 % |
Shrinkage rate | | ISO294-4 | 0.49 % |
Shrinkage rate | | ISO294-4 | 0.41 % |
Water absorption rate | | ASTMD570 | 1.1 % |
flammability | Test Condition | Test Method | Test Result |
---|
FlameRating | | UL94 | HB |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile strain | | ISO527-2 | 24 % |
Flexural modulus | | ASTMD790 | 2100 Mpa |
Flexural modulus | | ISO178 | 1980 Mpa |
bending strength | | ASTMD790 | 65.7 Mpa |
Bending stress | | ISO178 | 59.1 Mpa |
Tensile modulus | | ASTMD638 | 2070 Mpa |
Tensile modulus | | ISO527-2/1 | 2010 Mpa |
tensile strength | | ASTMD638 | 39.1 Mpa |
Tensile stress | | ISO527-2 | 38.0 Mpa |
tensile strength | | ASTMD638 | 36.7 Mpa |
Tensile stress | | ISO527-2 | 31.0 Mpa |
elongation | | ASTMD638 | 3.1 % |
Tensile strain | | ISO527-2 | 3.0 % |
elongation | | ASTMD638 | 6.0 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Suspended wall beam gap impact strength 3 | | ISO180/1A | 16 kJ/m² |
UnnotchedIzodImpactStrength3 | | ISO180/1U | NoBreak |
Dart impact equipped with measuring instruments | | ASTMD3763 | 32.8 J |
Multi axis Instrumented Impact Energy | | ISO6603-2 | 26.9 J |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | ASTMD257 | 1.0E+9to1.0E+11 ohms |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTMD648 | 88.9 °C |
Hot deformation temperature 4 | | ISO75-2/Bf | 91.0 °C |
| | ASTMD648 | 76.7 °C |
Hot deformation temperature 4 | | ISO75-2/Af | 76.0 °C |
| | ASTME831 | 9.3E-05 cm/cm/°C |
| | ISO11359-2 | 9.3E-05 cm/cm/°C |
| | ASTME831 | 1E-04 cm/cm/°C |
| | ISO11359-2 | 1E-04 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.