PS Stirofor® HI-V0 NATURALE

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTM D7921.17 g/cm³
melt mass-flow rateASTM D123815 g/10min
Shrinkage rate内部方法0.50 %
Water absorption rateASTM D5700.060 %
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94V-0
Hot filament ignition temperatureIEC 60695-2-13960 °C
Limiting Oxygen IndexASTM D286323 %
UL flame retardant ratingUL 94V-2
Mechanical propertiesTest ConditionTest MethodTest Result
tensile strength YieldASTM D63830.0 MPa
elongationBreakASTM D63820 %
Flexural modulusASTM D7902300 MPa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTM D25680 J/m
Electrical performanceTest ConditionTest MethodTest Result
Compared to the Leakage Tracking Index (CTI)IEC 60112PLC 2
needle flame testIEC 60695-11-5通过
Thermal performanceTest ConditionTest MethodTest Result
ball-indentation hardnessIEC 335通过
Heat distortion temperatureASTM D64877.0 °C
vicatASTM D1525385.0 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.