PA66 Amilan® CM3004G30 B TORAY SHENZHEN
33
- Properties:Flame retardantGlass fiber reinforced Glass fiber reinforced bFiller: Glass fiber reinfFlame retardant grade30%Filler by weighthalogen-containing Flame retardant grade30% filler by weighthalogen-containing
- Usages:Office suppliesAutomotive sectorbuilding materialsElectronic fieldElectrical field
Technical Data Sheet
| Other performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| filler content | 无水|30 wt% | ||
| 1.3%水|- wt% |
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Charpy Notched Impact Strength | -40°C | kJ/m² | 7.0 -- |
| 23°C | kJ/m² | 9.5 14 | |
| Impact strength of simply supported beam without notch | 23°C | kJ/m² | 65 70 |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | 0.40mm | V-0 -- |
| Basic Performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Water absorption rate | 23℃,24hr | ASTM D-570 | 无水|0.4 % |
| 23℃,24hr | ASTM D-570 | 1.3%水|- % |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of cantilever beam gap | 23℃,Unnotched1/8 | 无水|65 kg.cm/cm | |
| 23℃,Unnotched1/8 | 1.3%水|70 kg.cm/cm | ||
| tensile strength | 23℃,Break | ASTM D-638 | 无水|1640 kg/cm2 |
| 23℃,Break | ASTM D-638 | 1.3%水|1350 kg/cm2 | |
| Elongation at Break | 23℃ | ASTM D-638 | 无水|5 % |
| 23℃ | ASTM D-638 | 1.3%水|5 % | |
| bending strength | 23℃ | ASTM D-790 | 无水|2490 kg/cm2 |
| 23℃ | ASTM D-790 | 1.3%水|2000 kg/cm2 | |
| Bending modulus | 23℃ | ASTM D-790 | 无水|93200 kg/cm2 |
| 23℃ | ASTM D-790 | 1.3%水|65000 kg/cm2 | |
| Tensile strain | Break,-40°C | % | 2.5 -- |
| Break,23°C | % | 3.0 3.0 | |
| Break,80°C | % | 4.5 -- | |
| Bending modulus | -40°C | MPa | 10200 -- |
| 23°C | MPa | 9300 6500 | |
| 80°C | MPa | 5500 -- | |
| bending strength | -40°C | MPa | 275 -- |
| 23°C | 250 MPa | ||
| 80°C | MPa | 150 -- | |
| Taber abraser | 1000Cycles | mg | 26.0 -- |
| tensile strength | -40°C | MPa | 190 -- |
| 23°C | 165 MPa | ||
| 80°C | MPa | 110 -- |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Linear coefficient of thermal expansion | ASTM D-696 | 无水|2 10-5cm/cm.℃ | |
| ASTM D-696 | 1.3%水|- | ||
| Hot deformation temperature | 18.6kg/cm2 | ASTM D-648 | 无水|251 °C |
| 18.6kg/cm2 | ASTM D-648 | 1.3%水|- °C | |
| Melting temperature | 差示扫描测热计DSC法 | 265 °C | |
| UL-94 flame retardant grade | UL 94 | 无水|V-0 | |
| UL 94 | 1.3%水|- | ||
| Hot deformation temperature | 0.45MPa,Unannealed | °C | 251 -- |
| Melting temperature | °C | 265 -- | |
| Linear coefficient of thermal expansion | MD | cm/cm/°C | 2E-05 -- |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| density | ASTM D-792 | 无水|1.59 | |
| ASTM D-792 | 1.3%水|- | ||
| 23°C | g/cm³ | 1.59 -- | |
| Shrinkage rate | TD:3.00mm3 | % | 0.60-0.90 -- |
| MD:3.00mm4 | % | 0.20-0.50 -- | |
| Water absorption rate | 23°C,24hr | % | 0.60 -- |
| Saturation,23°C | % | 4.0 -- |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Volume resistivity | ASTM D-257 | 1.3%水|8×1013 Ω.cm | |
| Dielectric strength | 1/8" | ASTM D-149 | 无水|38 KV/mm |
| 1/8" | ASTM D-149 | 1.3%水|33 KV/mm | |
| Compared to the Leakage Traceability Index (CTI) | UL 746 | 无水|200 V | |
| UL 746 | 1.3%水|- V | ||
| Dissipation factor | 106Hz | ASTM D-150 | 无水|0.003-0.009 |
| 106Hz | ASTM D-150 | 1.3%水|- | |
| Arc resistance | 1/8" | ASTM D-495 | 无水|70-80 S |
| 1/8" | ASTM D-495 | 1.3%水|- S | |
| Volume resistivity | ASTM D-257 | 无水|8×1014 Ω.cm | |
| ohms·cm | 1E+15 1E+13 | ||
| Dielectric strength | kV/mm | 38 33 | |
| Dielectric constant | 23°C,1kHz | 4.00 -- | |
| 23°C,1MHz | 0.0100 -- | ||
| Arc resistance | sec | 70.0 -- | |
| Compared to the anti leakage trace index | CTI | V | PLC 3 |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Rockwell hardness | R-Sale,23°C | 121 -- |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.