Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
ThermalConductivityofMelt | | 内部方法 | 0.20 W/m/K |
Melt volume flow rate | | ISO1133 | 30.0 cm³/10min |
Shrinkage rate | | ISO294-4 | 0.80 % |
Shrinkage rate | | ISO294-4 | 0.30 % |
DensityMelt | | 内部方法 | 1.140 g/cm³ |
SpecificHeatCapacity of Melt | | 内部方法 | 1470 J/kg/°C |
density | | ISO1183 | 1.38 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | HB |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Flexural modulus | | ISO178 | 5800 MPa |
Bending stress | | ISO178 | 155 MPa |
Tensile modulus | | ISO527-2/1A/1 | 6400 MPa |
Tensile stress | Break | ISO527-2/1A/5 | 100 MPa |
Tensile strain | Break | ISO527-2/1A/5 | 2.3 % |
TensileCreepModule | | ISO899-1 | 6000 MPa |
Tensile creep modulus | | ISO899-1 | 4600 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO179/1eA | 7.0 kJ/m² |
Charpy Notched Impact Strength | | ISO179/1eA | 7.0 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 30 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 35 kJ/m² |
Impact strength of cantilever beam gap | | ISO180/1A | 6.0 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC60093 | >1.0E+15 ohms |
Volume resistivity | | IEC60093 | 1E+15 ohms·cm |
dielectric strength | | IEC60243-1 | 41 kV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO75-2/A | 253 °C |
Glass Transition Temperature | | ISO11357-2 | 105 °C |
| | ISO11359-2 | 3E-05 cm/cm/°C |
| | ISO11359-2 | 8E-05 cm/cm/°C |
melting temperature | | ISO11357-3 | 285 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.