physical property Test ConditionTest MethodTest Result
Melt volume flow rateISO 113330.0 cm³/10min
Melt volume flow rateISO 11339.00 cm³/10min
Shrinkage rateISO 294-40.60to0.80 %
Shrinkage rateISO 294-40.60to0.80 %
Water absorption rateISO 620.030 %
densityISO 11831.35 g/cm³
melt mass-flow rateASTM D123836 g/10min
melt mass-flow rateASTM D123811 g/10min
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94HB
Mechanical propertiesTest ConditionTest MethodTest Result
tensile strength YieldISO 527-2/5056.0 MPa
tensile strength ASTM D63846.0 MPa
tensile strength BreakISO 527-2/5049.0 MPa
elongationASTM D6388.7 %
elongationYieldISO 527-2/507.9 %
elongationASTM D63814 %
elongationBreakISO 527-2/5016 %
Flexural modulusASTM D7902350 MPa
Flexural modulusISO 1782620 MPa
Tensile modulusASTM D6382530 MPa
Tensile modulusISO 527-2/12490 MPa
tensile strength ASTM D63855.0 MPa
bending strengthISO 17895.0 MPa
bending strengthISO 17893.0 MPa
bending strengthASTM D79085.0 MPa
bending strengthASTM D79083.0 MPa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTM D256150 J/m
Impact strength of cantilever beam gapASTM D256280 J/m
Impact strength of cantilever beam gapISO 180/1A13 kJ/m²
Impact strength of cantilever beam gapISO 180/1A30 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Dissipation Factor内部方法9E-04
Dissipation Factor内部方法1.1E-03
Dissipation Factor内部方法1.9E-03
Dissipation Factor内部方法2.2E-03
dielectric constant内部方法3.56
dielectric constant内部方法3.57
dielectric constant内部方法3.57
dielectric constant内部方法3.58
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureASTM D648173 °C
Heat distortion temperatureISO 75-2/Bf173 °C
Heat distortion temperatureASTM D648154 °C
Heat distortion temperatureISO 75-2/Af155 °C
Linear coefficient of thermal expansionASTME8316.1E-05 cm/cm/°C
Linear coefficient of thermal expansionASTME8318.7E-05 cm/cm/°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.