Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ASTM D570 | 0.58 % |
Outdoor applicability | | UL 746C | f1 |
Water absorption rate | | ASTM D570 | 0.35 % |
Water absorption rate | | ASTM D570 | 0.15 % |
Shrinkage rate | | 内部方法 | 0.50-0.70 % |
melt mass-flow rate | | ASTM D1238 | 11 g/10min |
density | | ASTM D792 | 1.19 g/cm³ |
density | | ASTM D792 | 1.20 g/cm³ |
Specific volume | | ASTM D792 | 0.830 cm³/g |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | ASTM D785 | 118 |
Rockwell hardness | | ASTM D785 | 70 |
optical performance | Test Condition | Test Method | Test Result |
---|
Haze ratio | | ASTM D1003 | 1.0 % |
transmissivity | | ASTM D1003 | 88.0 % |
refractive index | | ASTM D542 | 1.586 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-2 |
Limiting Oxygen Index | | ASTM D2863 | 25 % |
UL flame retardant rating | | UL 94 | V-0 |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D4812 | 3200 J/m |
Impact strength of cantilever beam gap | | ASTM D1822 | 546 kJ/m² |
Dart impact | | ASTM D3029 | 169 J |
Impact strength of cantilever beam gap | | ASTM D256 | 800 J/m |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Taber abraser | | ASTM D1044 | 10.0 mg |
bending strength | | ASTM D790 | 93.1 Mpa |
Flexural modulus | | ASTM D790 | 2340 Mpa |
elongation | | ASTM D638 | 110 % |
elongation | | ASTM D638 | 7.0 % |
tensile strength | | ASTM D638 | 65.5 Mpa |
tensile strength | | ASTM D638 | 62.1 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Dissipation Factor | | ASTM D150 | 9E-04 |
Volume resistivity | | ASTM D257 | >1.0E+17 ohms·cm |
dielectric strength | | ASTM D149 | 15 KV/mm |
dielectric constant | | ASTM D150 | 3.17 |
dielectric constant | | ASTM D150 | 3.17 |
dielectric constant | | ASTM D150 | 2.96 |
Dissipation Factor | | ASTM D150 | 0.010 |
Dissipation Factor | | ASTM D150 | 9E-04 |
Hot wire ignition (HWI) | | UL 746 | PLC 4 |
High Voltage Arc Traceability Rate (HVTR) | | UL 746 | PLC 2 |
Compared to the Leakage Tracking Index (CTI) | | UL 746 | PLC 2 |
High arc combustion index (HAI) | | UL 746 | PLC 1 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
specific heat | | ASTMC351 | 1260 J/kg/°C |
Linear coefficient of thermal expansion | | ASTME831 | 6.8E-05 cm/cm/°C |
vicat | | ASTM D15255 | 154 °C |
Heat distortion temperature | | ASTM D648 | 132 °C |
Heat distortion temperature | | ASTM D648 | 138 °C |
RTI Imp | | UL 746 | 130 °C |
RTI Str | | UL 746 | 130 °C |
RTI Elec | | UL 746 | 130 °C |
thermal conductivity | | ASTMC177 | 0.27 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.