physical property | Test Condition | Test Method | Test Result |
---|
melt mass-flow rate | | ASTM D1238 | 12 g/10min |
Melt volume flow rate | | ISO 1133 | 11.5 cm3/10min |
Shrinkage rate | | 内部方法 | 0.40-0.60 % |
Shrinkage rate | | 内部方法 | 0.50-0.70 % |
Water absorption rate | | ISO 62 | 0.12 % |
Water absorption rate | | ISO 62 | 0.050 % |
optical performance | Test Condition | Test Method | Test Result |
---|
transmissivity | | ASTM D1003 | 88.0 % |
Haze ratio | | ASTM D1003 | 2.0 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-2 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
elongation | | ISO 527-2/50 | 130 % |
Flexural modulus | | ASTM D790 | 2300 Mpa |
Flexural modulus | | ISO 178 | 2260 Mpa |
bending strength | | ISO 178 | 92.0 Mpa |
bending strength | | ASTM D790 | 95.0 Mpa |
Tensile modulus | | ASTM D638 | 2150 Mpa |
Tensile modulus | | ISO 527-2/1 | 2300 Mpa |
tensile strength | | ASTM D638 | 60.0 Mpa |
tensile strength | | ISO 527-2/50 | 60.0 Mpa |
tensile strength | | ASTM D638 | 63.0 Mpa |
tensile strength | | ISO 527-2/50 | 62.0 Mpa |
elongation | | ASTM D638 | 6.3 % |
elongation | | ISO 527-2/50 | 5.8 % |
elongation | | ASTM D638 | 140 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179/1eA | 10 kJ/m² |
Dart impact | | ASTM D3763 | 77.0 J |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 119 °C |
Heat distortion temperature | | ASTM D648 | 106 °C |
Heat distortion temperature | | ISO 75-2/Af | 108 °C |
vicat | | ASTM D-596 | 126 °C |
vicat | | ISO 306/B50 | 125 °C |
Linear coefficient of thermal expansion | | ASTME831 | 1E-04 cm/cm/°C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 6.8E-05 cm/cm/°C |
Linear coefficient of thermal expansion | | ASTME831 | 1E-04 cm/cm/°C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 6.8E-05 cm/cm/°C |
thermal conductivity | | ISO 8302 | 0.23 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.