MMBS ZYLAR® 670

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
melt mass-flow rateASTM D12386.0 g/10min
Melt volume flow rateISO 11336.00 cm³/10min
Melt volume flow rateISO 113355.0 cm³/10min
Shrinkage rateASTM D9550.20to0.60 %
densityASTM D7921.05 g/cm³
densityISO 11831.05 g/cm³
Shrinkage rateISO 294-40.20to0.60 %
Water absorption rateASTM D5700.10 %
Water absorption rateISO 620.10 %
Water absorption rateISO 620.050 %
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessM-ScaleASTM D78570
Rockwell hardnessM-Scale70
optical performance Test ConditionTest MethodTest Result
refractive indexASTM D5421.560
refractive indexISO 4891.560
transmissivityASTM D100391.0 %
Haze ratioASTM D10032.0 %
Mechanical propertiesTest ConditionTest MethodTest Result
elongationBreakASTM D63842 %
Tensile strainISO 527-242 %
Flexural modulusASTM D7901830 MPa
Flexural modulusISO 1781800 MPa
bending strengthASTM D79041.4 MPa
bending strengthISO 17841.0 MPa
Tensile modulusASTM D6381830 MPa
Tensile modulusISO 527-21800 MPa
tensile strength ASTM D63827.6 MPa
tensile strength ISO 527-228.0 MPa
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO 1794.0 kJ/m²
Impact strength of simply supported beam without notchISO 179130 kJ/m²
Impact strength of cantilever beam gapASTM D256110 J/m
Impact strength of cantilever beam gapISO 180/A6.0 kJ/m²
Suspended wall beam without notch impact strengthISO 180140 kJ/m²
Dart impactASTM D54207.91 J
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC 60093>1.0E+14 ohms
Volume resistivityIEC 60093>1.0E+15 ohms·cm
dielectric constantIEC 602502.50
Thermal performanceTest ConditionTest MethodTest Result
vicatASTM D1525297.8 °C
vicatISO 306/B5072.0 °C
maximum service temperature250 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.