plas
Log In

TPO PRE-ELEC® PP 1383 Premix Oy

0

Technical Data Sheet

impact performanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gap23°CISO 1809.0 kJ/m²
Suspended wall beam without notch impact strength-20°C,4.00mmASTM D25654.6 kJ/m²
Suspended wall beam without notch impact strength23°C,4.00mmASTM D25660.9 kJ/m²
Suspended wall beam without notch impact strength-20°CISO 18055 kJ/m²
Suspended wall beam without notch impact strength23°CISO 18059 kJ/m²
Charpy Notched Impact Strength-20°CASTM D2568.4 kJ/m²
Charpy Notched Impact Strength-20°CISO 1799.0 kJ/m²
Charpy Notched Impact Strength23°CISO 17912 kJ/m²
Charpy Notched Impact Strength23°CASTM D25611 kJ/m²
Impact strength of simply supported beam without notch-20°CASTM D256NoBreak
Impact strength of simply supported beam without notch-20°CISO 179NoBreak
Impact strength of simply supported beam without notch23°CISO 179NoBreak
Impact strength of simply supported beam without notch23°CASTM D256NoBreak
Impact strength of cantilever beam gap-20°C,4.00mm,AreaASTM D2564.20 kJ/m²
Impact strength of cantilever beam gap23°C,4.00mm,AreaASTM D2568.41 kJ/m²
Impact strength of cantilever beam gap-20°CISO 1805.0 kJ/m²
mechanical propertiesTest ConditionTest MethodTest Result
elongationBreakASTM D6385.0 %
tensile strengthASTM D63825.0 MPa
tensile strengthISO 527-225.0 MPa
Tensile strainBreakISO 527-25.0 %
Bending modulus4.00mmASTM D7901310 MPa
Bending modulus4.00mmISO 1781300 MPa
thermal performanceTest ConditionTest MethodTest Result
Hot deformation temperature0.45MPa,UnannealedASTM D648B100 °C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/Bf100 °C
Vicat softening temperatureASTM D15253149 °C
Vicat softening temperatureISO 306/A50150 °C
Physical propertiesTest ConditionTest MethodTest Result
melt mass-flow rate230°C/2.16kgISO 113314 g/10min
Shrinkage rateMDASTM D9551.2to1.4 %
Shrinkage rateMDISO 294-41.2to1.4 %
densityASTM D7920.996 g/cm³
densityISO 11830.990 g/cm³
melt mass-flow rate230°C/2.16kgASTM D123814 g/10min
Electrical performanceTest ConditionTest MethodTest Result
Surface resistivityESDSTM11.11<1.0E+3 ohms
Surface resistivityIEC 61340-2-3<1.0E+3 ohms
Volume resistivityInternal Method<1.0E+2 ohms·cm
hardnessTest ConditionTest MethodTest Result
Shore hardnessShoreAASTM D224095
Shore hardnessShoreDASTM D224065
Shore hardnessShoreAISO 86895
Shore hardnessShoreDISO 86865
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.