Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO1183 | 1.05 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | V-2 |
UL flame retardant rating | | UL94 | V-0 |
Burning wire flammability index | | IEC60695-2-12 | 960 °C |
Hot filament ignition temperature | | IEC60695-2-13 | 875 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO527-2 | 2500 MPa |
Tensile stress | | ISO527-2 | 25.0 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ISO180/1A | 2.5 kJ/m² |
Impact strength of cantilever beam gap | | ISO180/1A | 3.5 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | IEC60093 | 1E+15 ohms·cm |
CTI | | IEC60112 | 600 V |
Surface Resistivity | | IEC60093 | 1E+15 ohms |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO75-2/A | 60.0 °C |
melting temperature | | ISO11357-3 | 165到170 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.