PAS RTP 1605 TFE 15

0
  • Properties:
    Filler
    glass fiber reinforced material
    30%
    filler by weight

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTM D7921.70 g/cm³
Shrinkage rateASTM D9550.20 %
Water absorption rateASTM D5700.20 %
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessR-ScaleASTM D785120
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94V-0
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusASTM D63811700 MPa
tensile strength ASTM D638110 MPa
elongationBreakASTM D6381.0 %
Flexural modulusASTM D7909650 MPa
bending strengthASTM D790145 MPa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTM D25691 J/m
Suspended wall beam without notch impact strengthASTM D4812350 J/m
Electrical performanceTest ConditionTest MethodTest Result
Volume resistivityASTM D2571E+16 ohms·cm
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureASTM D648207 °C
Heat distortion temperatureASTM D648204 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.