PPS LUVOCOM® 1301-0915 LEHVOSS Group
0
- Properties:Filler carbon fiber reinforced material
- Usages:Textile applications medical nursing supplies automotive applications business equipment engineering accessories
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1fU | 19 kJ/m² |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Bending strain | ISO 178 | 1.5 % | |
| bending strength | ISO 178 | 175 MPa | |
| Bending modulus | ISO 178 | 10000 MPa | |
| Tensile strain | Yield | ISO 527-2 | 1.2 % |
| tensile strength | Break | ISO 527-2 | 125 MPa |
| Tensile modulus | ISO 527-2 | 13000 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Linear coefficient of thermal expansion | MD | DIN 53752 | 3E-05 cm/cm/°C |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 220 °C |
| Maximum operating temperature | ShortTerm | 240 °C | |
| Continuous use temperature | UL 746B | 220 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Water absorption rate | 23°C,24hr | <0.050 % | |
| Shrinkage rate | DIN 16901 | 0.20to0.50 % | |
| density | ISO 1183 | 1.49 g/cm³ |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| insulation resistance | IEC 60167 | <1.0E+5 ohms | |
| Surface resistivity | IEC 60093 | <1.0E+3 ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.