Technical Data Sheet
物理性能 | Test Condition | Test Method | Test Result |
---|
流动方向:24小时 | | ISO294-4 | 0.55 % |
吸水率 | 23°C,24hr | ISO62 | 0.23 % |
流动1 | | 内部方法 | 0.70 % |
流动:24小时 | | ASTMD955 | 0.55 % |
横向流动:24小时 | | ASTMD955 | 0.65 % |
垂直流动方向:24小时 | | ISO294-4 | 0.65 % |
热性能 | Test Condition | Test Method | Test Result |
---|
BallPressureTest | 165°C | IEC60695-10-2 | Pass |
流动:-40到40°C | | ASTME831 | 3.3E-05 cm/cm/°C |
流动:-30到80°C | | ISO11359-2 | 3.9E-05 cm/cm/°C |
横向:-40到40°C | | ASTME831 | 4.4E-05 cm/cm/°C |
横向:-30到80°C | | ISO11359-2 | 5.5E-05 cm/cm/°C |
导热系数 | --13 | ISO22007-2 | 1.2 W/m/K |
导热系数 | --14 | ISO22007-2 | 5.5 W/m/K |
0.45MPa,未退火,3.20mm | | ASTMD648 | 203 °C |
0.45MPa,未退火,64.0mm跨距11 | | ISO75-2/Bf | 203 °C |
1.8MPa,未退火,3.20mm | | ASTMD648 | 137 °C |
1.8MPa,未退火,64.0mm跨距12 | | ISO75-2/Af | 160 °C |
可燃性 | Test Condition | Test Method | Test Result |
---|
UL阻燃等级 | 0.800mm | UL94 | V-0 |
灼热丝易燃指数 | 0.800mm | IEC60695-2-12 | 960 °C |
热灯丝点火温度 | 0.800mm | IEC60695-2-13 | 750 °C |
热灯丝点火温度 | 1.60mm | IEC60695-2-13 | 775 °C |
热灯丝点火温度 | 3.00mm | IEC60695-2-13 | 800 °C |
电气性能 | Test Condition | Test Method | Test Result |
---|
漏电起痕指数 | | IEC60112 | 600 V |
高电弧燃烧指数(HAI) | HAI | UL746 | PLC 0 |
热丝引燃(HWI) | HWI | UL746 | PLC 0 |
表面电阻率 | | ASTMD257 | 4E+14 ohms |
介电强度 | 1.60mm,inOil | ASTMD149 | 7.2 KV/mm |
相比耐漏电起痕指数(CTI) | CTI | UL746 | PLC 0 |
机械性能 | Test Condition | Test Method | Test Result |
---|
--2 | | ASTMD638 | 10400 Mpa |
屈服3 | | ASTMD638 | 68.0 Mpa |
断裂 | | ISO527-2/5 | 75.0 Mpa |
断裂4 | | ASTMD638 | 1.2 % |
断裂 | | ISO527-2/5 | 1.1 % |
50.0mm跨距5 | | ASTMD790 | 11800 Mpa |
--6 | | ISO178 | 12000 Mpa |
--7 | | ISO178 | 105 Mpa |
断裂,50.0mm跨距8 | | ASTMD790 | 119 Mpa |
冲击性能 | Test Condition | Test Method | Test Result |
---|
23°C | | ASTMD256 | 15 J/m |
23°C9 | | ISO180/1A | 3.0 kJ/m² |
23°C | | ASTMD4812 | 150 J/m |
23°C10 | | ISO180/1U | 9.0 kJ/m² |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.