PEI ULTEM™ 9085 WH8E479
42
- Properties:High mobilityLow toxicityLow smoke
- Usages:Railway Applicationsnational defenseProfileAircraft interior parts
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
melt mass-flow rate | ASTM D1238 | 8.9 g/10min | |
Melt volume flow rate | ISO 1133 | 65.5 cm3/10min | |
Shrinkage rate | 内部方法 | 0.50-0.70 % | |
Water absorption rate | ISO 62 | 0.39 % | |
ISO 62 | 0.17 % |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
Limiting Oxygen Index | ASTM D2863 | 49 % | |
FAAFlammability | FAR25.853 | <5 | |
OSU peak heat release rate | FAR25.853 | 36.0 kW/m² | |
OSU total heat release | FAR25.853 | 16.0 kW·min/m² | |
VerticalBurnTest | FAR25.853 | 2.0 sec |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile strain | ISO 527-2/5 | 6.7 % | |
elongation | ASTM D638 | 72 % | |
Tensile strain | ISO 527-2/5 | 50 % | |
Flexural modulus | ASTM D790 | 2920 Mpa | |
ISO 178 | 2750 Mpa | ||
bending strength | ISO 178 | 90.0 Mpa | |
ASTM D790 | 138 Mpa | ||
Tensile modulus | ASTM D638 | 3440 Mpa | |
ISO 527-2/1 | 3050 Mpa | ||
tensile strength | ASTM D638 | 84.0 Mpa | |
ISO 527-2/5 | 88.0 Mpa | ||
ASTM D638 | 74.0 Mpa | ||
ISO 527-2/5 | 71.0 Mpa | ||
elongation | ASTM D638 | 7.0 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ISO 180/1A | 13 kJ/m² |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D648 | 153 °C | |
ISO 75-2/Af | 152 °C | ||
vicat | ISO 306/B120 | 173 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.