Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.03to1.35 g/cm³ |
density | | ISO 1183 | 1.06to1.07 g/cm³ |
Shrinkage rate | | ASTM D955 | 0.23to2.0 % |
Shrinkage rate | | ASTM D955 | 1.1to2.0 % |
Shrinkage rate | | ISO 294-4 | 1.1to1.8 % |
Water absorption rate | | ASTM D570 | 0.13to0.38 % |
Water absorption rate | | ASTM D570 | 3.0to4.0 % |
Water absorption rate | | ISO 62 | 2.1to3.0 % |
Water absorption rate | | ISO 62 | 0.88to1.3 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | ASTM D785 | 108to115 |
flammability | Test Condition | Test Method | Test Result |
---|
Burning wire flammability index | | IEC 60695-2-12 | 719to725 °C |
Hot filament ignition temperature | | IEC 60695-2-13 | 700to750 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
bending strength | | ASTM D790 | 23.0to296 MPa |
bending strength | | ISO 178 | 28.5to71.1 MPa |
coefficient of friction | | ASTM D1894 | 0.13to1.0 |
Flexural modulus | | ISO 178 | 1300to2110 MPa |
tensile strength | | ASTM D638 | 45.0to65.0 MPa |
tensile strength | | ISO 527-2 | 48.6to62.4 MPa |
tensile strength | | ISO 527-2 | 30.0to141 MPa |
tensile strength | | ASTM D638 | 31.4to173 MPa |
elongation | | ASTM D638 | 3.2to40 % |
elongation | | ISO 527-2 | 4.0to5.1 % |
elongation | | ASTM D638 | 2.5to300 % |
elongation | | ISO 527-2 | 2.5to55 % |
Nominal tensile fracture strain | | ISO 527-2 | 17to300 % |
Flexural modulus | | ASTM D790 | 1770to8640 MPa |
Tensile modulus | | ASTM D638 | 1650to2540 MPa |
Tensile modulus | | ISO 527-2 | 275to7950 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179 | 3.5to12 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179 | 29to96 kJ/m² |
Impact strength of cantilever beam gap | | ASTM D256 | 36to81 J/m |
Impact strength of cantilever beam gap | | ISO 180 | 3.7to5.3 kJ/m² |
Suspended wall beam without notch impact strength | | ASTM D256 | 560to1300 J/m |
Impact strength of cantilever beam gap | | ASTM D1822 | 126to945 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | IEC 60243-1 | 22to37 kV/mm |
dielectric constant | | ASTM D150 | 3.48to6.00 |
Volume resistivity | | ASTM D257 | 55到1.0E+15 ohms·cm |
Volume resistivity | | IEC 60093 | 1.0E+10到2.5E+15 ohms·cm |
dielectric constant | | IEC 60250 | 4.14 |
Dissipation Factor | | ASTM D150 | 0.017to0.15 |
Dissipation Factor | | IEC 60250 | 0.014to0.15 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 0 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
melting temperature | | ISO 3146 | 200to211 °C |
Linear coefficient of thermal expansion | | ASTM D696 | 4.9E-5到9.0E-5 cm/cm/°C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 8.6E-5到2.0E-4 cm/cm/°C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 9.0E-5到1.8E-4 cm/cm/°C |
Heat distortion temperature | | ISO 75-2/A | 51.7to75.1 °C |
vicat | | ISO 306 | 108to201 °C |
melting temperature | | | 208to215 °C |
melting temperature | | ISO 11357-3 | 215to218 °C |
Heat distortion temperature | | ASTM D648 | 132to212 °C |
Heat distortion temperature | | ISO 75-2/B | 134to172 °C |
Heat distortion temperature | | ASTM D648 | 54.1to216 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.