physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | 内部方法 | 0.40-0.60 % | |
Water absorption rate | ISO 62 | 0.050 % | |
ISO 62 | 0.20 % | ||
density | ASTM D792 | 1.20 g/cm³ | |
ISO 1183 | 1.17 g/cm³ | ||
melt mass-flow rate | ASTM D1238 | 15 g/10min | |
Melt volume flow rate | ISO 1133 | 15.0 cm3/10min | |
Shrinkage rate | 内部方法 | 0.50-0.80 % |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Shore hardness | ASTM D2240 | 74 |
optical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
refractive index | ISO 489 | 1.539 | |
transmissivity | ASTM D1003 | 88.0 % | |
Haze ratio | ASTM D1003 | 1.0 % |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | V-2 | |
Burning wire flammability index | IEC 60695-2-12 | 750 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ASTM D638 | 1520 Mpa | |
ISO 527-2/1 | 1600 Mpa | ||
tensile strength | ASTM D638 | 47.0 Mpa | |
ISO 527-2/50 | 55.0 Mpa | ||
ASTM D638 | 46.0 Mpa | ||
ISO 527-2/50 | 54.0 Mpa | ||
elongation | ASTM D638 | 5.0 % | |
Tensile strain | ISO 527-2/50 | >5.0 % | |
elongation | ASTM D638 | 150 % | |
Tensile strain | ISO 527-2/50 | >200 % | |
Flexural modulus | ASTM D790 | 1680 Mpa | |
ISO 178 | 1700 Mpa | ||
bending strength | ISO 178 | 78.0 Mpa | |
ASTM D790 | 71.0 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ISO 180/1A | 7.0 kJ/m² | |
ISO 180/1A | 5.0 kJ/m² | ||
ISO 180/1A | 8.0 kJ/m² | ||
Dart impact | ASTM D3763 | 95.0 J | |
Charpy Notched Impact Strength | ISO 179/1eA | 10 kJ/m² | |
Impact strength of cantilever beam gap | ASTM D256 | 73 J/m | |
ASTM D256 | 1100 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | ASTM D257 | >1.0E+15 ohms | |
Volume resistivity | ASTM D257 | >1.0E+15 ohms·cm | |
Compared to the Leakage Tracking Index (CTI) | UL 746 | PLC 0 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
vicat | ISO 306/B120 | 96.0 °C | |
ball-indentation hardness | IEC 60695-10-2 | Pass | |
Linear coefficient of thermal expansion | ASTME831 | 1.1E-04 cm/cm/°C | |
ISO 11359-2 | 1.1E-04 cm/cm/°C | ||
ISO 11359-2 | 9E-05 cm/cm/°C | ||
ASTME831 | 1.1E-04 cm/cm/°C | ||
ISO 11359-2 | 1.1E-04 cm/cm/°C | ||
ISO 11359-2 | 9E-05 cm/cm/°C | ||
thermal conductivity | ISO 8302 | 0.23 W/m/K | |
Heat distortion temperature | ASTM D648 | 79.0 °C | |
ASTM D648 | 75.0 °C | ||
ISO 75-2/Ae | 80.0 °C | ||
ISO 75-2/Af | 78.0 °C | ||
vicat | ASTM D152511 | 91.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.