Technical Data Sheet
物理性能 | Test Condition | Test Method | Test Result |
---|
密度 / 比重2 | | ASTMD792 | 1.17 g/cm³ |
密度 | 23°C | ISO1183 | 1.17 g/cm³ |
熔体质量流动速率 | 260°C/2.16kg | ASTMD1238 | 20 g/10min |
熔体体积流动速率 | 260°C/2.16kg | ISO1133 | 21.0 cm3/10min |
SpiralFlow3,4 | | 内部方法 | 45.0 CM |
收缩率 | MD | ASTMD955 | 0.40to0.60 % |
收缩率 | | ISO2577 | 0.40to0.60 % |
热性能 | Test Condition | Test Method | Test Result |
---|
线性热膨胀系数 | MD:23到55°C | ISO11359-2 | 8E-05 cm/cm/°C |
热变形温度9 | 1.8MPa,未退火,3.20mm | ASTMD648 | 78.0 °C |
热变形温度9 | 1.8MPa,未退火,6.40mm | ASTMD648 | 87.0 °C |
热变形温度9 | 1.8MPa,Unannealed,4.00mm | ISO75-2/A | 73.0 °C |
维卡软化温度 | -- | ASTMD152510 | 94.0 °C |
维卡软化温度 | -- | ASTMD152511 | 85.0 °C |
维卡软化温度 | -- | ISO306/A50 | 94.0 °C |
维卡软化温度 | -- | ISO306/B50 | 85.0 °C |
可燃性 | Test Condition | Test Method | Test Result |
---|
UL阻燃等级 | 1.5mm | UL94 | V-0 |
UL阻燃等级 | 2.1mm | UL94 | 5VB |
UL阻燃等级 | 3.0mm | UL94 | 5VA |
电气性能 | Test Condition | Test Method | Test Result |
---|
表面电阻率 | | IEC60093 | 2.9E+17 ohms |
体积电阻率 | | IEC60093 | 3.9E+19 ohms·cm |
介电常数 | 1MHz | IEC60250 | 3.10 |
机械性能 | Test Condition | Test Method | Test Result |
---|
拉伸应变5 | Break,23°C | ASTMD638 | 100 % |
拉伸应变 | 断裂 | ISO527-2/50 | 110 % |
弯曲模量6 | 23°C | ASTMD790 | 245 Mpa |
弯曲模量7 | | ISO178 | 2500 Mpa |
FlexuralStrength6 | 23°C | ASTMD790 | 78.5 Mpa |
弯曲应力7 | | ISO178 | 80.0 Mpa |
拉伸强度5 | Yield,23°C | ASTMD638 | 49.0 Mpa |
拉伸应力 | 屈服 | ISO527-2/50 | 55.0 Mpa |
拉伸应力 | 断裂 | ISO527-2/50 | 45.0 Mpa |
硬度 | Test Condition | Test Method | Test Result |
---|
洛氏硬度 | R计秤,23°C | ASTMD785 | 113 |
洛氏硬度 | R计秤,23°C | ISO2039-2 | 113 |
冲击性能 | Test Condition | Test Method | Test Result |
---|
悬壁梁缺口冲击强度 | 23°C | ISO180 | 45 kJ/m² |
简支梁缺口冲击强度8 | -30°C | ISO179 | 15 kJ/m² |
简支梁缺口冲击强度8 | 23°C | ISO179 | 45 kJ/m² |
悬壁梁缺口冲击强度 | 23°C,3.18mm | ASTMD256 | 590 J/m |
悬壁梁缺口冲击强度 | -30°C | ISO180 | 15 kJ/m² |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.