Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ISO 2577 | 0.50to0.61 % |
Shrinkage rate | | ISO 2577 | 0.40to0.49 % |
density | | ASTM D792 | 1.24 g/cm³ |
density | | ISO 1183 | 1.24 g/cm³ |
melt mass-flow rate | | ASTM D1238 | 20 g/10min |
melt mass-flow rate | | ISO 1133 | 20 g/10min |
Shrinkage rate | | ASTM D955 | 0.40to0.49 % |
Shrinkage rate | | ASTM D955 | 0.50to0.61 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | R-Scale | ASTM D785 | 117 |
Rockwell hardness | R-Scale | ISO 2039-2 | 117 |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179/1eA | 10 kJ/m² |
Impact strength of cantilever beam gap | | ASTM D256 | 88 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 69 J/m |
Impact strength of cantilever beam gap | | ISO 180/1A | 10 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTM D638 | 8400 MPa |
Tensile modulus | | ISO 527-2/50 | 8800 MPa |
tensile strength | Yield | ASTM D638 | 140 MPa |
Flexural modulus | | ISO 178 | 11000 MPa |
bending strength | | ASTM D790 | 240 MPa |
bending strength | | ISO 178 | 210 MPa |
Flexural modulus | | ASTM D790 | 5900 MPa |
tensile strength | Yield | ISO 527-2/50 | 159 MPa |
tensile strength | Break | ASTM D638 | 140 MPa |
tensile strength | Break | ISO 527-2/50 | 160 MPa |
elongation | Break | ASTM D638 | 3.0 % |
Tensile strain | Break | ISO 527-2/50 | 3.0 % |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 250 °C |
Heat distortion temperature | | ISO 75-2/B | 254 °C |
Heat distortion temperature | | ASTM D648 | 231 °C |
Heat distortion temperature | | ISO 75-2/A | 234 °C |
vicat | | ISO 306/B50 | 248 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.