Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
transmittance | | ASTM D-1003 | 半透明 % |
processability | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ASTM D-955 | 0.2-0.4 % |
Shrinkage rate | | ASTM D-955 | 0.4-0.6 % |
Basic performance | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ASTM D-570 | 0.15 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Flexural modulus | | ASTM D-790 | 4410(45000) MPa(Kgf/cm |
Rockwell hardness | | ASTM D-785 | 90 M标度 |
tensile strength | | ASTM D-638 | 94(960) |
bending strength | | ASTM D-790 | 142(1450) MPa(Kgf/cm |
Impact strength of cantilever beam gap | | ASTM D-256 | 120(12) J/m(kgf·cm/cm) |
elongation | | ASTM D-638 | 5 |
compressive strength | | ASTM D-695 | 120(1220) MPa(Kgf/cm |
Tensile modulus | | ASTM D-638 | 5000(51000) MPa(Kgf/cm |
Impact strength of cantilever beam gap | | ASTM D-256 | 120(12) J/m(kgf·cm/cm) |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Dielectric loss | | ASTM D-150 | 0.0008 |
dielectric constant | | ASTM D-150 | 3.32 |
Volume resistivity | | ASTM D-257 | 1 |
arc resistance | | ASTM D-495 | 100 sec |
dielectric constant | | ASTM D-150 | 3.23 |
dielectric strength | | ASTM D-149 | 30 KV/mm |
Dielectric loss | | ASTM D-150 | 0.009 |
Conductive Track Resistance (CTI) | | IEC 112 | 175 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
TEMPERATURE | | UL 746B | 130 °C |
TEMPERATURE | | UL 746B | 125 °C |
TEMPERATURE | | UL 746B | 130 °C |
Linear coefficient of thermal expansion | | ASTM D-696 | 3.2 |
Linear coefficient of thermal expansion | | ASTM D-696 | 6.5 |
Heat distortion temperature | | ASTM D-648 | 150 °C |
Heat distortion temperature | | ASTM D-648 | 147 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.