PBT+PET SCHULADUR® A1 GF 50

0
  • Properties:
    Filler
    glass fiber reinforced material
    50%
    filler by weight

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
Melt volume flow rateISO 113320.0 cm³/10min
densityISO 1183/A1.75 g/cm³
flammabilityTest ConditionTest MethodTest Result
Hot filament ignition temperatureIEC 60695-2-13700 °C
Hot filament ignition temperatureIEC 60695-2-13800 °C
burning rateISO 379525 mm/min
UL flame retardant ratingIEC 60695-11-10,-20HB
UL flame retardant ratingIEC 60695-11-10,-20HB
Burning wire flammability indexIEC 60695-2-12725 °C
Burning wire flammability indexIEC 60695-2-12825 °C
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of simply supported beam without notchISO 179/1eU60 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA10 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA10 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU60 kJ/m²
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO 527-2/1A/118500 MPa
tensile strength BreakISO 527-2/1A/5175 MPa
Tensile strainBreakISO 527-2/1A/51.5 %
Flexural modulusISO 17816000 MPa
bending strengthISO 178245 MPa
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureISO 75-2/Bf220 °C
Heat distortion temperatureISO 75-2/Af203 °C
vicatISO 306/A50218 °C
vicatISO 306/B50201 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.