Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ISO 62 | 0.30 % |
Water absorption rate | | ISO 62 | 0.10 % |
Viscosity value | | ISO 1628 | 91.0 ml/g |
density | | ISO 1183 | 1.55 g/cm³ |
Apparent density | | ISO 60 | 0.80 g/cm³ |
Melt volume flow rate | | ISO 1133 | 30.0 cm³/10min |
Shrinkage rate | | ISO 294-4 | 0.90 % |
Shrinkage rate | | ISO 294-4 | 0.20 % |
Shrinkage rate | | ISO 294-4 | 0.30 % |
Shrinkage rate | | ISO 294-4 | 0.10 % |
hardness | Test Condition | Test Method | Test Result |
---|
ball-indentation hardness | | ISO 2039-1 | 200 MPa |
flammability | Test Condition | Test Method | Test Result |
---|
Burning Behavior | | ISO 3795 | passed |
Burning wire flammability index | | IEC 60695-2-12 | 750 °C |
Limiting Oxygen Index | | ISO 4589-2 | 21 % |
UL flame retardant rating | | UL 94 | HB |
UL flame retardant rating | | UL 94 | HB |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
electrolytic corrosion | | IEC 60426 | A1 |
ISO Shortcut | | ISO 7792 | PBT+PET.GHMR.09-100.GF30 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
bending strength | | ASTM D790 | 207 MPa |
bending strength | | ISO 178 | 230 MPa |
Bending Strain | | | 3.0 % |
Tensile modulus | | ASTM D638 | 9980 MPa |
Tensile modulus | | ISO 527-2/1 | 10400 MPa |
tensile strength | | ASTM D638 | 123 MPa |
tensile strength | | ISO 527-2/5 | 145 MPa |
elongation | | ASTM D638 | 2.5 % |
Tensile strain | | ISO 527-2/5 | 2.8 % |
Tensile creep modulus | | ISO 899-1 | 10000 MPa |
Tensile creep modulus | | ISO 899-1 | 8500 MPa |
Flexural modulus | | ASTM D790 | 8550 MPa |
Flexural modulus | | ISO 178/A | 10300 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179/1eA | <10 kJ/m² |
Charpy Notched Impact Strength | | ISO 179/1eA | <10 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | 55 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | 65 kJ/m² |
Impact strength of cantilever beam gap | | ISO 180/1A | <10 kJ/m² |
Impact strength of cantilever beam gap | | ISO 180/1A | <10 kJ/m² |
Impact strength of cantilever beam gap | | ISO 180/1A | <10 kJ/m² |
Suspended wall beam without notch impact strength | | ISO 180/1U | 55 kJ/m² |
Suspended wall beam without notch impact strength | | ISO 180/1U | 55 kJ/m² |
film | Test Condition | Test Method | Test Result |
---|
Thin film puncture strength | | ISO 6603-2 | 2.10 J |
Thin film puncture strength | | ISO 6603-2 | 650 N |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | IEC 60243-1 | 27 kV/mm |
relative permittivity | | IEC 60250 | 4.00 |
relative permittivity | | IEC 60250 | 3.80 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 2 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/A | 200 °C |
vicat | | ISO 306/B120 | 205 °C |
ball-indentation hardness | | IEC 60695-10-2 | Pass |
melting temperature | | ISO 11357-3 | 225to250 °C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 3E-05 cm/cm/°C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 9E-05 cm/cm/°C |
thermal conductivity | | ISO 8302 | 0.27 W/m/K |
RTI Elec | | UL 746 | 140 °C |
RTI Imp | | UL 746 | 125 °C |
RTI Str | | UL 746 | 140 °C |
Half Interval | | IEC 60216 | 10.2 °C |
Half Interval | | IEC 60216 | 13.5 °C |
Half Interval | | IEC 60216 | 10.2 °C |
TemperatureIndex | | IEC 60216 | 155 |
Heat distortion temperature | | ISO 75-2/B | 220 °C |
TemperatureIndex | | IEC 60216 | 140 |
TemperatureIndex | | IEC 60216 | 155 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.