PAS RTP 1605 Z RTP US

0
  • Properties:
    Filler
    glass fiber reinforced material
    30%
    filler by weight

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTM D7921.59 g/cm³
Shrinkage rateASTM D9550.10 %
Water absorption rateASTM D5700.36 %
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessR-ScaleASTM D785123
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94V-0
Impact resistanceTest ConditionTest MethodTest Result
Suspended wall beam without notch impact strengthASTM D4812530 J/m
Impact strength of cantilever beam gapASTM D25680 J/m
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusASTM D6388960 MPa
tensile strength ASTM D638124 MPa
elongationBreakASTM D6382.0 %
Flexural modulusASTM D7907580 MPa
bending strengthASTM D790172 MPa
compressive strengthASTM D695124 MPa
Electrical performanceTest ConditionTest MethodTest Result
dielectric strengthASTM D14916 kV/mm
dielectric constantASTM D1504.30
Dissipation FactorASTM D1508E-03
Volume resistivityASTM D2571E+16 ohms·cm
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureASTM D648221 °C
Heat distortion temperatureASTM D648213 °C
Linear coefficient of thermal expansionASTM D6962.7E-05 cm/cm/°C
thermal conductivityASTMC1770.32 W/m/K
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.