Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ISO 294-4 | 0.50 % |
Shrinkage rate | | ISO 294-4 | 0.40 - 0.70 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2/1 | 2800 Mpa |
tensile strength | | ISO 527-2 | 57.0 Mpa |
tensile strength | | ISO 527-2 | 55.0 Mpa |
Tensile strain | | ISO 527-2 | 3.8 % |
Tensile strain | | ISO 527-2 | 4.0 to 8.0 % |
Flexural modulus | | ISO 178 | 2600 Mpa |
bending strength | | ISO 178 | 80.0 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Suspended wall beam without notch impact strength | | ASTM D4812 | 1800 J/m |
Suspended wall beam without notch impact strength | | ISO 180/1U | 85 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | ASTM D257 | 1.0E+2 - 1.0E+3 ohms |
Volume resistivity | | ASTM D257 | 1.0E+4 ohms·cm |
Electromagnetic shielding effectiveness (EMI) | | 内部方法 | 40 to 55 dB |
injection | Test Condition | Test Method | Test Result |
---|
drying temperature | | | 120 °C |
drying time | | | 4.0 hr |
Suggested maximum moisture content | | | 0.020 % |
Temperature at the rear of the barrel | | | 295 to 305 °C |
Temperature in the middle of the barrel | | | 310 to 320 °C |
Temperature at the front of the material cylinder | | | 320 to 330 °C |
Processing (melt) temperature | | | 305 to 325 °C |
Temperature | | | 95 to 120 °C |
Back pressure | | | 0.200 to 0.300 Mpa |
screw speed | | | 30 to 60 rpm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/Bf | 136 °C |
Heat distortion temperature | | ISO 75-2/Af | 125 °C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 6.7E-5 cm/cm/°C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 5.6E-5 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.