PC TRISTAR® PC-10R-CL(22)

0
  • Usages:
    Electrical and electronic application fields
    communication equipment

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTMD7921.20 g/cm³
melt mass-flow rateASTMD123822 g/10min
Water absorption rateASTMD5700.15 %
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessR-ScaleASTMD785120
optical performance Test ConditionTest MethodTest Result
refractive indexASTMD5421.586
transmissivityASTMD100389.0 %
Haze ratioASTMD10031.0 %
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL94V-2
Burning wire flammability indexIEC60695-2-12960 °C
Hot filament ignition temperatureIEC60695-2-13775 °C
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTMD256750 J/m
Mechanical propertiesTest ConditionTest MethodTest Result
tensile strengthASTMD63860.3 MPa
elongationASTMD638120 %
Flexural modulusASTMD7902410 MPa
bending strengthASTMD79089.6 MPa
Electrical performanceTest ConditionTest MethodTest Result
Hot wire ignition (HWI)UL746PLC 3
Hot wire ignition (HWI)UL746PLC 2
Compared to the Leakage Tracking Index (CTI)UL746250到400 V
Compared to the Leakage Tracking Index (CTI)UL746PLC 2
High arc combustion index (HAI)UL746>120
High arc combustion index (HAI)UL74660.0到120
High arc combustion index (HAI)UL746PLC 0
High arc combustion index (HAI)UL746PLC 1
High Voltage Arc Traceability Rate (HVTR)UL74680.0到150 mm/min
High Voltage Arc Traceability Rate (HVTR)UL746PLC 3
Hot wire ignition (HWI)UL74615到30 sec
Hot wire ignition (HWI)UL74630到60 sec
arc resistanceASTMD49560.0到120 sec
arc resistanceASTMD495PLC6
Thermal performanceTest ConditionTest MethodTest Result
Heat Deflection TemperatureASTMD648127 °C
Heat Deflection TemperatureISO75-2/A137 °C
Linear thermal expansion coefficientASTME8317E-05 cm/cm/°C
Linear thermal expansion coefficientASTME8316.8E-05 cm/cm/°C
RTI ElecUL746125 °C
RTI ImpUL746115 °C
RTIUL746125 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.