Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO 1183 | 1.42 g/cm³ |
Shrinkage rate | | 内部方法 | 0.50 - 0.80 % |
Shrinkage rate | | 内部方法 | 0.10 - 0.40 % |
Water absorption rate | | ISO 62 | 0.02 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2 | 10600 Mpa |
tensile strength | | ISO 527-2 | 115 Mpa |
Tensile strain | | ISO 527-2 | 1.6 % |
Flexural modulus | | ISO 178 | 10000 Mpa |
bending strength | | ISO 178 | 170 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179 | 10 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179 | 28 kJ/m² |
Impact strength of cantilever beam gap | | ISO 180 | 9 kJ/m² |
Suspended wall beam without notch impact strength | | ISO 180 | 29 kJ/m² |
Flame retardant performance | Test Condition | Test Method | Test Result |
---|
> 1.50 mm> 1.5 mm | | UL 94 | V-0 |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | IEC 60093 | > 1.0E+16 ohms·cm |
dielectric strength | | ASTM D149 | 35 KV/mm |
dielectric constant | | IEC 60250 | 3 |
Dissipation Factor | | IEC 60250 | 0.002 |
arc resistance | | ASTM D495 | PLC 6 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 0 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/A | 245 °C |
Heat distortion temperature | | ISO 75-2/B | 265 °C |
Linear coefficient of thermal expansion | | TMA | 0.000040 1/℃ |
Linear coefficient of thermal expansion | | TMA | 0.000020 1/℃ |
Relative Heat Index (RTI) | | UL 746 | 50 °C |
Relative Heat Index (RTI) | | UL 746 | 50 °C |
Relative Heat Index (RTI) | | UL 746 | 50 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.