Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.26 g/cm³ |
density | | ISO 1183 | 1.27 g/cm³ |
melt mass-flow rate | | ASTM D1238 | 24 g/10min |
Melt volume flow rate | | ISO 1133 | 16.0 cm³/10min |
Shrinkage rate | | 内部方法 | 0.50to0.70 % |
Shrinkage rate | | 内部方法 | 0.50to0.70 % |
Water absorption rate | | ISO 62 | 0.90 % |
Water absorption rate | | ISO 62 | 0.50 % |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
Metallic haze | | 内部方法 | 195 °C |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 53 J/m |
Impact strength of cantilever beam gap | | ISO 180/1A | 5.0 kJ/m² |
Impact strength of cantilever beam gap | | ISO 180/1A | 5.0 kJ/m² |
Impact strength of cantilever beam gap | | ASTM D4812 | 2100 J/m |
Charpy Notched Impact Strength | | ISO 179/1eA | 4.0 kJ/m² |
Charpy Notched Impact Strength | | ISO 179/1eA | 4.0 kJ/m² |
Impact strength of cantilever beam gap | | ASTM D256 | 2100 J/m |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
elongation | Break | ASTM D638 | 70 % |
Flexural modulus | | ASTM D790 | 3170 MPa |
Flexural modulus | | ISO 178 | 3100 MPa |
bending strength | | ASTM D790 | 145 MPa |
Tensile modulus | | ISO 527-2/1 | 3000 MPa |
tensile strength | Yield | ASTM D638 | 96.5 MPa |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Linear coefficient of thermal expansion | | ISO 11359-2 | 6E-05 cm/cm/°C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 6E-05 cm/cm/°C |
thermal conductivity | | ISO 8302 | 0.23 W/m/K |
Heat distortion temperature | | ISO 75-2/Be | 195 °C |
Heat distortion temperature | | ASTM D648 | 190 °C |
Heat distortion temperature | | ISO 75-2/Ae | 180 °C |
vicat | | ISO 306/B120 | 205 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.