Unspecified polyvic® M-1848-GV 05 Unipack Plasindo

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTM D7921.31 g/cm³
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessR-ScaleASTM D78514
Shore hardnessASTM D224076
optical performance Test ConditionTest MethodTest Result
transmissivityASTM D100390.0 %
flammabilityTest ConditionTest MethodTest Result
burning rateASTM D6354.4 mm/min
Supplementary InformationTest ConditionTest MethodTest Result
XenonLampTest-UVLifePeriod/TimetoYellowness5.5 month
Mechanical propertiesTest ConditionTest MethodTest Result
tensile strength ASTM D63847.7 MPa
elongationBreakASTM D638180 %
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTM D25664.6 kJ/m²
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureASTM D64852.9 °C
vicatASTM D25678.2 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.