Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

Unspecified polyvic® M-1848-GV 05 Unipack Plasindo
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| Supplementary Information | Test Condition | Test Method | Unipack Plasindo/polyvic® M-1848-GV 05 |
|---|---|---|---|
| XenonLampTest-UVLifePeriod/TimetoYellowness | 5.5 month |
| hardness | Test Condition | Test Method | Unipack Plasindo/polyvic® M-1848-GV 05 |
|---|---|---|---|
| Rockwell hardness | R-Scale | ASTM D785 | 14 |
| Shore hardness | ShoreD | ASTM D2240 | 76 |
| thermal performance | Test Condition | Test Method | Unipack Plasindo/polyvic® M-1848-GV 05 |
|---|---|---|---|
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 52.9 °C |
| Vicat softening temperature | ASTM D256 | 78.2 °C |
| mechanical properties | Test Condition | Test Method | Unipack Plasindo/polyvic® M-1848-GV 05 |
|---|---|---|---|
| elongation | Break | ASTM D638 | 180 % |
| tensile strength | ASTM D638 | 47.7 MPa |
| Physical properties | Test Condition | Test Method | Unipack Plasindo/polyvic® M-1848-GV 05 |
|---|---|---|---|
| density | ASTM D792 | 1.31 g/cm³ |
| impact performance | Test Condition | Test Method | Unipack Plasindo/polyvic® M-1848-GV 05 |
|---|---|---|---|
| Impact strength of cantilever beam gap | Area | ASTM D256 | 64.6 kJ/m² |
| flammability | Test Condition | Test Method | Unipack Plasindo/polyvic® M-1848-GV 05 |
|---|---|---|---|
| Burning rate | ASTM D635 | 4.4 mm/min |
| optical performance | Test Condition | Test Method | Unipack Plasindo/polyvic® M-1848-GV 05 |
|---|---|---|---|
| transmissivity | ASTM D1003 | 90.0 % |