Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Melt volume flow rate | | ISO1133 | 8.50 cm3/10min |
Shrinkage rate | | 内部方法 | 0.40到0.60 % |
Water absorption rate | | ISO62 | 0.32 % |
Water absorption rate | | ISO62 | 0.13 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | ISO2039-2 | 120 |
| | ISO2039-1 | 100 Mpa |
optical performance | Test Condition | Test Method | Test Result |
---|
refractive index | | ISO489 | 1.586 |
transmissivity | | ASTMD1003 | 88.0到90.0 % |
Haze ratio | | ASTMD1003 | <0.80 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | V-2 |
UL flame retardant rating | | UL94 | V-0 |
Burning wire flammability index | | IEC60695-2-12 | 850 °C |
Burning wire flammability index | | IEC60695-2-12 | 960 °C |
Limiting Oxygen Index | | ISO4589-2 | 40 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Suspended wall beam gap impact strength 7 | | ISO180/1A | 8.0 kJ/m² |
| | ISO180/1U | 无断裂 |
| | ISO180/1U | 无断裂 |
Impact strength of simply supported beam gap 6 | | ISO179/1eA | 9.0 kJ/m² |
Impact strength of simply supported beam gap 6 | | ISO179/1eA | 9.0 kJ/m² |
Simple supported beam without notch impact strength 6 | | ISO179/1eU | 无断裂 |
Simple supported beam without notch impact strength 6 | | ISO179/1eU | 无断裂 |
Suspended wall beam gap impact strength 7 | | ISO180/1A | 8.0 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile strain | | ISO527-2/50 | 6.0 % |
Tensile strain | | ISO527-2/50 | 100 % |
Flexural modulus | | ISO178 | 2300 Mpa |
Bending stress 4,5 | | ISO178 | 95.0 Mpa |
| | 内部方法 | 9.00 mg |
Tensile modulus | | ISO527-2/1 | 2350 Mpa |
Tensile stress | | ISO527-2/50 | 65.0 Mpa |
Tensile stress | | ISO527-2/50 | 70.0 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC60093 | >1.0E+15 ohms |
Volume resistivity | | IEC60093 | >1.0E+15 ohms·cm |
dielectric strength | | IEC60243-1 | 35 KV/mm |
dielectric strength | | IEC60243-1 | 27 KV/mm |
dielectric strength | | IEC60243-1 | 17 KV/mm |
| | IEC60250 | 2.70 |
| | IEC60250 | 2.70 |
| | IEC60250 | 2.70 |
Dissipation Factor | | IEC60250 | 1E-03 |
Dissipation Factor | | IEC60250 | 1E-03 |
Dissipation Factor | | IEC60250 | 0.010 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
thermal conductivity | | ISO8302 | 0.20 W/m/K |
RTI Elec | | UL746 | 80.0 °C |
RTI Imp | | UL746 | 80.0 °C |
RTI | | UL746 | 80.0 °C |
| | ISO75-2/Be | 140 °C |
| | ISO75-2/Ae | 129 °C |
vicat | | ISO306/B50 | 144 °C |
vicat | | ISO306/B120 | 145 °C |
BallPressure Test | | IEC60695-10-2 | 通过 |
BallPressure Test | | IEC60695-10-2 | 通过 |
| | ISO11359-2 | 7E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.