Technical Data Sheet
Test Condition | Test Method | Test Result | |
---|---|---|---|
UL flame retardant rating | UL 94 | V-0 | |
UL 94 | V-0 | ||
UL 94 | 5VA | ||
IEC 60695-11-10,-20 | V-0 | ||
IEC 60695-11-10,-20 | V-0 | ||
IEC 60695-11-10,-20 | 5VA | ||
Burning wire flammability index | IEC 60695-2-12 | 960 °C | |
IEC 60695-2-12 | 960 °C | ||
density | ISO 1183/A | 1.30 g/cm³ | |
Melt volume flow rate | ISO 1133 | 12.0 cm³/10min | |
Tensile modulus | ISO 527-2/1A/1 | 2500 MPa | |
burning rate | ISO 3795 | 0.0 mm/min | |
ISO 3795 | 0.0 mm/min | ||
Heat distortion temperature | ISO 75-2/Bf | 113 °C | |
ISO 75-2/Af | 60.0 °C | ||
vicat | ISO 306/A50 | 190 °C | |
ISO 306/B50 | 156 °C | ||
ball-indentation hardness | IEC 60695-10-2 | Pass | |
RTI Elec | UL 746 | 60.0 °C | |
UL 746 | 60.0 °C | ||
RTI Imp | UL 746 | 60.0 °C | |
UL 746 | 60.0 °C | ||
RTI Str | UL 746 | 60.060.0 °C | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 3 | |
Burning wire flammability index | IEC 60695-2-12 | 960 °C | |
Hot filament ignition temperature | IEC 60695-2-13 | 750 °C | |
IEC 60695-2-13 | 750 °C | ||
Limiting Oxygen Index | ISO 4589-2 | 31 % | |
tensile strength | Yield | ISO 527-2/1A/50 | 52.0 MPa |
Tensile strain | Yield | ISO 527-2/1A/50 | 3.0 % |
Charpy Notched Impact Strength | ISO 179/1eA | 9.0 kJ/m² | |
ISO 179/1eA | 12 kJ/m² | ||
Impact strength of simply supported beam without notch | ISO 179/1eU | NoBreak | |
ISO 179/1eU | NoBreak |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.