Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183 | 1.04 g/cm³ | |
Shrinkage rate | ISO 294-4 | 1.5 to 2.0 % | |
Water absorption rate | ISO 62 | 0.030 % | |
ISO 62 | 0.010 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
bending strength | ISO 178 | 30.0 MPa | |
Impact strength of cantilever beam gap | ISO 180/1A | 9.0 kJ/m² | |
Suspended wall beam without notch impact strength | ISO 180/1U | 无断裂 | |
Tensile strain | Break | ISO 527-2 | > 100 % |
Flexural modulus | ISO 178 | 1700 MPa | |
tensile strength | Break | ISO 527-2 | 20.0 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | ASTM D257 | 1E+15 ohm | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 0 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 75-2/A | 55.0 ℃ | |
Linear coefficient of thermal expansion | ISO 11359-2 | 1.5E-06 cm/cm/℃ | |
RTI Imp | UL 746 | 75.0 ℃ | |
UL flame retardant rating | UL 94 | V-0 | |
Burning wire flammability index | IEC 60695-2-12 | 960 ℃ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.