ABS AG15A1-H FCFC TAIWAN
509
Form:Granules | Color:Transparent natural color | Grade:Injection grade
Properties:
High glossModerate impactUniversal level
Typical Applications:
calculatorClock housingPhonesuitcaseToySound enclosure
Product Description
Certificates(8)
Datasheet
Product Description
| Typical Applications: | calculator | Clock housing | Phone | suitcase | Toy | Sound enclosure |
| Properties: | High gloss | Moderate impact | Universal level |
| Color: | Transparent natural color |
Certificates
TDS
Processing



SVHC
PSC
TDS
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| FlameRating | 1.5mm,AllColors | UL94 | HB | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R计秤,23°C | ISO2039-2 | 110 | |
| R计秤,23°C | ASTMD785 | 110 | ||
| Impact strength of cantilever beam gap | 23°C,6.35mm | ASTMD256 | 220 | J/m |
| 23°C,4.00mm | ISO180 | 25 | k/Jm2 | |
| bending strength | 23°C | ISO178 | 73 | Mpa |
| 23°C | ASTMD790 | 830 | kg/cm2 | |
| Bending modulus | 23°C | ISO178 | 2550 | Mpa |
| 23°C | ASTMD790 | 26000 | kg/cm2 | |
| tensile strength | 屈服,23°C | ISO527-2 | 47.0 | Mpa |
| 23°C | ASTMD638 | 43 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | ISO306/A | 93 | °C | |
| ASTMD15253 | 93 | °C | ||
| Hot deformation temperature | 1.8MPa,Annealed,6.35mm | ASTMD648 | 92.0 | °C |
| 1.8MPa,Unannealed,6.35mm | ISO75-2/A | 86.0 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 200°C/5.0kg | ISO1133 | 2.2 | g/10min |
| 220°C/10.0kg | ASTMD1238 | 22 | g/10min | |
| density | 23°C | ISO1183 | 1.04 | g/cm³ |
| ASTMD792 | 1.04 | g/cm³ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.