Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ASTM D955 | 0.5-0.7 % |
Water absorption rate | | ASTM D570 | 0.2 % |
Network Finance Index | | ASTM D1238 | 10 g/10min |
optical performance | Test Condition | Test Method | Test Result |
---|
transmissivity | | ASTM D1003 | 89 % |
Jiadu | | ASTM DI 003 | 0.8 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTM D638 | 2250 Mpa |
tensile strength | | ASTM D638 | 70 Mpa |
Tensile strength yield | | ASTM D638 | 65 Mpa |
| | ASTM D638 | 100 % |
bending strength | | ASTM D790 | 95 Mpa |
Flexural modulus | | ASTM D790 | 2300 Mpa |
| | ASTM D256 | 800 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Accumulation resistor | | IEC 60093 | 100000000000000 Ω.m |
Surface Resistivity | | IEC 60093 | 10000000000000000 Ω |
isolation | | IEC 60243 | 34 KV/mm |
dielectric constant | | IEC 60250 | 3.1 |
dielectric constant | | IEC 60250 | 3 |
| | IEC 60250 | 0.00050 |
| | IEC 60250 | 0.009 |
proof tracking index | | IEC 60112 | 225 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTM D648 | 126 °C |
vicat | | ASTM D1525 | 146 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.