Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.47 g/cm³ |
density | | ISO 1183 | 1.47 g/cm³ |
Melt volume flow rate | | ISO 1133 | 20.0 cm³/10min |
Shrinkage rate | | | 0.30 % |
Shrinkage rate | | ISO 294-4 | 0.75 % |
Shrinkage rate | | ISO 294-4 | 0.29 % |
Water absorption rate | Saturation | ASTM D570 | 0.40 % |
Water absorption rate | | ISO 62 | 0.40 % |
Water absorption rate | | ASTM D570 | 0.20 % |
Water absorption rate | | ISO 62 | 0.20 % |
Viscosity value | | ISO 1628 | 105.0 ml/g |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | HB |
UL flame retardant rating | | UL 94 | HB |
UL flame retardant rating | | UL 94 | HB |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile strain | | ISO 527-2 | 2.2 % |
Tensile strain | | ISO 527-2 | 3.6 % |
Tensile strain | | ISO 527-2 | 5.9 % |
Tensile strain | | ISO 527-2 | 4.8 % |
Tensile creep modulus | | ISO 899-1 | 7600 MPa |
tensile strength | | ISO 527-2 | 79.0 MPa |
tensile strength | | ISO 527-2 | 47.0 MPa |
tensile strength | | ISO 527-2 | 35.0 MPa |
elongation | | ASTM D638 | 2.2 % |
Tensile strain | | ISO 527-2 | 2.4 % |
bending strength | | ASTM D790 | 194 MPa |
Tensile modulus | | ISO 527-2 | 9700 MPa |
tensile strength | | ASTM D638 | 125 MPa |
tensile strength | | ISO 527-2 | 195 MPa |
tensile strength | | ISO 527-2 | 125 MPa |
Tensile creep modulus | | ISO 899-1 | 6700 MPa |
Flexural modulus | | ASTM D790 | 8270 MPa |
Flexural modulus | | ISO 178 | 8300 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179 | 9.0 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179 | 50 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179 | 59 kJ/m² |
Impact strength of cantilever beam gap | | ASTM D256 | 69 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 85 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric constant | | IEC 60250 | 3.80 |
dielectric constant | | IEC 60250 | 3.70 |
Dissipation Factor | | IEC 60250 | 3E-03 |
Dissipation Factor | | IEC 60250 | 0.018 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 1 |
Surface Resistivity | | ASTM D257 | 1E+14 ohms |
Surface Resistivity | | IEC 60093 | 1E+14 ohms |
Volume resistivity | | ASTM D257 | >1.0E+13 ohms·cm |
Volume resistivity | | IEC 60093 | >1.0E+13 ohms·cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 210 °C |
RTI Elec | | UL 746 | 130 °C |
RTI Elec | | UL 746 | 130 °C |
Heat distortion temperature | | ISO 75-2/B | 210 °C |
Heat distortion temperature | | ASTM D648 | 177 °C |
Heat distortion temperature | | ISO 75-2/A | 175 °C |
melting temperature | | ASTM D3418 | 223 °C |
melting temperature | | ISO 3146 | 223 °C |
Linear coefficient of thermal expansion | | | 4E-05 cm/cm/°C |
RTI Elec | | UL 746 | 130 °C |
RTI Imp | | UL 746 | 90.0 °C |
RTI Imp | | UL 746 | 90.0 °C |
RTI Str | | UL 746 | 130 °C |
RTI Str | | UL 746 | 130 °C |
RTI Str | | UL 746 | 130 °C |
RTI Imp | | UL 746 | 90.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.